The microbeam system at Tohoku University

Author:

Matsuyama S.1

Affiliation:

1. Department of Quantum Science and Energy Engineering, Tohoku University, Aramaki-aza-Aoba 6-6-01-2, Aoba-ku, Sendai 980-8579, Japan

Abstract

A microbeam system called MB-I was developed at the Dynamitron laboratory at Tohoku University in 2002 for use in biological applications. Although the system was designed to achieve a submicron beam spot size, parasitic field contamination from tungsten carbide slit chips and an annular Si surface barrier detector have limited the beam spot size to [Formula: see text]. By replacing these components, parasitic field contamination of the system was reduced and the performance of the microbeam system was remarkably improved. A measured beam spot size of [Formula: see text] at a beam current of several tens of pA has been achieved. MB-I has been used for simultaneous in-air/in-vacuum particle-induced X-ray emission (PIXE), Rutherford backscattering spectroscopy (RBS), secondary electron (SE), scanning transmission ion microscopy (STIM) analyses, and three-dimensional PIXE micron computed tomography (PIXEμCT), with applications in various fields. To obtain a higher spatial resolution of several hundred nm and a higher beam current with a resolution of several μm, a triplet lens system was designed and installed in MB-I. The triplet system has a larger demagnification than the existing system; however, it also has larger chromatic and spherical aberration coefficients. Therefore, stricter requirements are imposed on the accelerator performance, particularly the beam brightness and energy stability. In addition to the microbeam, the Dynamitron accelerator was also upgraded to obtain a higher beam brightness. The beam brightness is [Formula: see text], with a half-divergence of 0.07 mrad. The energy resolution of the accelerator was improved by developing a terminal voltage stabilization system (TVSS), to achieve an energy resolution of [Formula: see text]. Thus, the effects of the increased chromatic and spherical aberration were mitigated by restricting the divergence angle, without reducing the beam current. A beam spot size of [Formula: see text] was obtained with a beam current of 150 pA. While the analysis system of MB-I can be used for simultaneous in-air/vacuum PIXE, RBS and STIM analyses, as well as 3D PIXEμCT, without changing the target chamber, changes are required in the experimental setup for these techniques, which is time-consuming, Thus, a new microbeam system, MB-II, was developed. The MB-II is a doublet system and is not equipped with a high-resolution energy analysis system. It is connected to a switching magnet. The beam brightness is [Formula: see text] at a half-divergence of 0.1 mrad and this does not decrease as the beam divergence increases. This property is matched to obtain a higher beam current using the doublet system. With a current of 300 pA, the MB-II provides a higher beam current for a [Formula: see text] beam spot size than is achievable with the MB-I. At present, both microbeam systems are in routine operation at the Dynamitron laboratory.

Publisher

World Scientific Pub Co Pte Lt

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3