Affiliation:
1. Department of Electrical Engineering Laboratory Research SIME, ENSIT, Av. Taha Hussein Montfleury, 1008 Tunis-Tunisia, Tunisia
Abstract
Self-excited induction generators (SEIG) are found to be most suitable candidate for wind energy conversion application required at remote windy locations. The major drawbacks of these generators are the poor voltage and frequency control under load and prime mover speed perturbations. In this paper, an attempt has been made to optimize the control strategy under various load and prime mover conditions, of the self-excited wound rotor induction generator (SEWRIG). By tolerating a slight deviation of the output voltage and ensuring a constant frequency with an adequate external rotor resistance, only four values of excitation capacitor are required for the whole range of operation. The effectiveness of the adopted strategy has been confirmed by comparing on a 0.8-[Formula: see text]kW wound rotor induction generator the simulated results to the corresponding obtained with an experimental test. A close agreement between the computed and experimental results confirms the efficiency of the adopted method.
Publisher
World Scientific Pub Co Pte Lt
Subject
Electrical and Electronic Engineering,Hardware and Architecture,Electrical and Electronic Engineering,Hardware and Architecture
Cited by