Basis of using ultrasound elastography in diffuse and focal liver diseases

Author:

Morozova T. G.1,Borsukov A. V.1

Affiliation:

1. Smolensk State Medical University of the Ministry of Health of Russian Federation

Abstract

Objective:to develop the basics of ultrasound elastography for diffuse and focal liver diseases.Material and methods.180 patients were examined, including 102 (56.7%) men and 78 (43.3%) women. Patients were hospitalized in the gastroenterological and surgical departments: 100 (55.6%) patients with diffuse liver disease (DLD), 80 (44.4%) with focal liver pathology (FLP). All elastographic techniques were used; The liver biopsy served as the reference method (n = 169 (93.8%)).Results.If a patient has steatohepatitis, it is recommended to begin research with transient elastography (TE), in hepatitis – with compression elastography (CE), according to the study, it is determined that shear wave elastography (SWE) is informative in all clinical forms of DLD. The terms of elastographic monitoring have been developed: upon admission, after 6, 9, 12 months. With dynamic observation of patients, elastographic techniques have a high diagnostic and prognostic value with stable and positive clinical laboratory and instrumental dynamics (liver biopsy – AUROC 0,882, DI 0.741–0.699, elastography – AUROC 0,991, DI 0.779–0.997). At FLP the results of SWE help in determining the “zone of interest” for the subsequent conduct of a morphological study, with the aim of establishing a diagnosis.Conclusions.1. In the presence of a patient with steatohepatitis, it is recommended to begin research with TE, in hepatitis with CE, according to the results of the study, it is determined that SWE is informative in all clinical forms of DLD. 2. Dynamic elastographic monitoring in case of DLD should be performed at admission, after 6, 9 and 12 months, and then individually for each patient. 3. With dynamic observation of patients with DLD, elastographic techniques have a high diagnostic and prognostic value with stable and positive clinical laboratory and instrumental dynamics (liver biopsy – AUROC 0.882, DI 0.741–0.66, elastography – AUROC 0.991, DI 0.779–0.997). 4. It has been established that the results of all elastographic techniques can not be used as differential diagnostic tools, SWE helps in choosing a “zone of interest” for biopsy with subsequent verification of the diagnosis (AUROC 0.907 (95% DI 0.889–0.933)).

Publisher

Vidar, Ltd.

Subject

Literature and Literary Theory,History,Cultural Studies

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3