Volumetric analysis on computed tomography Angiography in the management of thoracic aortic dissection in case of seven years follow-up period

Author:

Kobelev E.1ORCID,Shadanov A. A.1ORCID,Sirota D. A.1ORCID,Bergen T. A.1ORCID,Pak N. T.1ORCID,Chernyavskiy M. A.1ORCID

Affiliation:

1. Meshalkin National Medical Research Center of Russian Federation Ministry of Health

Abstract

Purpose. To establish the methods for estimating the volume of the true and false aortic canals applying computed tomography angiography (CTA) to a clinical case with hybrid stent-graft thoracic aorta with distal stent-graftinduced new entry associated (d-SINE) in the long-term follow-up period in comparison with a widely used technique of measuring diameters of the aorta on different levels.Materials and methods. Sequential analysis of CTA in a 7-year follow-up was performed. Aorta was divided into 3 segments, in each segment total aortic volumes (AV), volume of the true canal (TC), and volume of functional lumen of the false canal (FLFC) were calculated. The following were mathematically calculated: volume of the false canal (FC) via difference in volume between AV and TC, volume of the thrombosed lumen of FC as the difference between FC and FLFC, the coefficient of FC thrombosis, the degree of stent-graft opening. Mathematical assessment of excess volume of the graft was performed.Results. Modelling of aortic cavity, evaluation of changes in the volumes of TC and FC during a long-term follow-up, analysis of the factors inducing the development of the d-SINE syndrome were performed. When comparing the volume of the graft and the volume of the implantation zone, an excess of 234% was found, while the opening of the graft was 80%. When using the reference method based on the diameter of the true lumen of the aorta, the excess was 22% during one-year follow-up period showing no changes subsequently.Conclusion. Potentially, the method of measuring volumes based on CTA results can be used to complement the generally accepted method based on measuring diameters, since it does not require additional financial resources and has the potential to estimate effectiveness of treatment and identify complications predictors in the postoperative period to determine indications for reoperation. 

Publisher

Vidar, Ltd.

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3