Abstract
AbstractHuman induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) have become an essential tool to study arrhythmia mechanisms. Much of the foundational work on these cells, and the computational models built from the resultant data, has overlooked the contribution of seal-leak current on the immature and heterogeneous phenotype that has come to define these cells. Here, we usein silicoandin vitrostudies to demonstrate how seal-leak current depolarises action potentials (APs), substantially affecting their morphology, even with seal resistances (Rseal) above 1 GΩ. We show that compensation of this leak current is difficult due to challenges with recording accurate measures of Rsealduring an experiment. Using simulation, we show that Rsealmeasures: 1) change during an experiment, invalidating the use of pre-rupture values, and 2) are polluted by the presence of transmembrane currents at every voltage. Finally, we posit the background sodium current in baseline iPSC-CM models imitates the effects of seal-leak current and is increased to a level that masks the effects of seal-leak current on iPSC-CMs. Based on these findings, we make three recommendations to improve iPSC-CM AP data acquisition, interpretation, and model-building. Taking these recommendations into account will improve our understanding of iPSC-CM physiology and the descriptive ability of models built from such data.Key pointsHuman induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) are an essential tool in the study of cardiac arrhythmia mechanisms.Their immature and heterogeneous action potential phenotype complicates the interpretation of experimental data, and has slowed their acceptance in industry and academia.We suggest that a leak current caused by an imperfect pipette-membrane seal during single-cell patch-clamp experiments is partly responsible for inducing this phenotype.Usingin vitroexperiments and computational modelling, we show that this seal-leak current affects iPSC-CM AP morphology, even under ‘ideal’ experimental conditions.Based on these findings, we make recommendations that should be considered when interpreting, analysing and fitting iPSC-CM data.
Publisher
Cold Spring Harbor Laboratory
Reference40 articles.
1. Anthropomorphizing the mouse cardiac action potential via a novel dynamic clamp method;Biophysical Journal,2009
2. Automated Dynamic Clamp for Simulation of IK1 in Human Induced Pluripotent Stem Cell–Derived Cardiomyocytes in Real Time Using Patchliner Dynamite8;Current Protocols in Pharmacology,2020
3. Clinical Trial in a Dish: Personalized Stem Cell–Derived Cardiomyocyte Assay Compared With Clinical Trial Results for Two QT-Prolonging Drugs;Clinical and Translational Science,2019
4. A computer simulation of the effect of heart rate on ion concentrations in the heart
5. An in silico-in vitro pipeline for drug cardiotoxicity screening identifies ionic proarrhythmia mechanisms;British journal of pharmacology,2022
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献