Attaching artificial Achilles and tibialis cranialis tendons to bone using suture anchors in a rabbit model: assessment of outcomes

Author:

Fidelis Obinna P.,Stubbs Caleb,Easton Katrina L.,Billings Caroline,Pedersen Alisha P.,Anderson David E.,Crouch Dustin L.

Abstract

ABSTRACTObjectiveThe purpose of this study was to investigate the factors associated with outcomes of attaching artificial tendons to bone using suture anchors for replacement of biological tendons in rabbits.Study DesignMetal suture anchors with braided composite sutures of varying sizes (USP #1, #2, or #5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, n=8), or four weeks after (delayed replacement, n=4) resection of the biological tendon. Hindlimb radiographs of the rabbits were obtained immediately after surgery and approximately every other week until the study endpoint (16 weeks post-surgery).ResultsAll suture anchors used for the tibialis cranialis artificial tendons remained secure and did not fail during the study. The suture linkage between the Achilles artificial tendon and anchor failed in 9 of 12 rabbits. In all cases, the mode of failure was suture breakage distant from the knot. Based on radiographic analysis, the mean estimated failure timepoint was 5.3±2.3 weeks post-surgery, with a range of 2-10 weeks. Analysis of variance (ANOVA) tests revealed no significant effect of tendon implantation timing or suture size on either the timing or frequency of suture anchor failure.ConclusionBased on the mode of failure, suture mechanical properties, and suture anchor design, we suspect that the cause of failure was wear of the suture against the edges of the eyelet in the suture anchor post, which reduced the suture strength below in vivo loads. Suture anchor designs differed for the tibialis cranialis and did not fail during the period of study. Future studies are needed to optimize suture anchor mechanical performance under different loading conditions and suture anchor design features.

Publisher

Cold Spring Harbor Laboratory

Reference33 articles.

1. Bone anchoring of sutures for adequate repositioning of the soft tissue flaps in one stage dental implants

2. Arthrex Inc. (2014). Revolutionalizing orthopaedic surgery https://www.arthrex.com/resources/LB1-0235-EN/fiberwire-braided-composite-suture?referringteam=shoulder

3. Suture anchor failure strength – an in vivo study;Arthroscopy – The Journal of Arthroscopic Study and Related Surgery,1993

4. The ultimate strength of suture anchors;Arthroscopy: The Journal of Arthroscopic and Related Surgery,1995

5. Sutures and anchors – update 2006;Arthroscopy: The Journal of Arthroscopic and Related Surgery,2006

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3