Author:
Fidelis Obinna P.,Stubbs Caleb,Easton Katrina L.,Billings Caroline,Pedersen Alisha P.,Anderson David E.,Crouch Dustin L.
Abstract
ABSTRACTObjectiveThe purpose of this study was to investigate the factors associated with outcomes of attaching artificial tendons to bone using suture anchors for replacement of biological tendons in rabbits.Study DesignMetal suture anchors with braided composite sutures of varying sizes (USP #1, #2, or #5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, n=8), or four weeks after (delayed replacement, n=4) resection of the biological tendon. Hindlimb radiographs of the rabbits were obtained immediately after surgery and approximately every other week until the study endpoint (16 weeks post-surgery).ResultsAll suture anchors used for the tibialis cranialis artificial tendons remained secure and did not fail during the study. The suture linkage between the Achilles artificial tendon and anchor failed in 9 of 12 rabbits. In all cases, the mode of failure was suture breakage distant from the knot. Based on radiographic analysis, the mean estimated failure timepoint was 5.3±2.3 weeks post-surgery, with a range of 2-10 weeks. Analysis of variance (ANOVA) tests revealed no significant effect of tendon implantation timing or suture size on either the timing or frequency of suture anchor failure.ConclusionBased on the mode of failure, suture mechanical properties, and suture anchor design, we suspect that the cause of failure was wear of the suture against the edges of the eyelet in the suture anchor post, which reduced the suture strength below in vivo loads. Suture anchor designs differed for the tibialis cranialis and did not fail during the period of study. Future studies are needed to optimize suture anchor mechanical performance under different loading conditions and suture anchor design features.
Publisher
Cold Spring Harbor Laboratory
Reference33 articles.
1. Bone anchoring of sutures for adequate repositioning of the soft tissue flaps in one stage dental implants
2. Arthrex Inc. (2014). Revolutionalizing orthopaedic surgery https://www.arthrex.com/resources/LB1-0235-EN/fiberwire-braided-composite-suture?referringteam=shoulder
3. Suture anchor failure strength – an in vivo study;Arthroscopy – The Journal of Arthroscopic Study and Related Surgery,1993
4. The ultimate strength of suture anchors;Arthroscopy: The Journal of Arthroscopic and Related Surgery,1995
5. Sutures and anchors – update 2006;Arthroscopy: The Journal of Arthroscopic and Related Surgery,2006