Automated quality control of T1-weighted brain MRI scans for clinical research: methods comparison and design of a quality prediction classifier

Author:

Bhalerao GauravORCID,Gillis GraceORCID,Dembele MohamedORCID,Suri SanaORCID,Ebmeier KlausORCID,Klein Johannes,Hu MicheleORCID,Mackay ClareORCID,Griffanti LudovicaORCID

Abstract

AbstractIntroductionT1-weighted MRI is widely used in clinical neuroimaging for studying brain structure and its changes, including those related to neurodegenerative diseases, and as anatomical reference for analysing other modalities. Ensuring high-quality T1-weighted scans is vital as image quality affects reliability of outcome measures. However, visual inspection can be subjective and time-consuming, especially with large datasets. The effectiveness of automated quality control (QC) tools for clinical cohorts remains uncertain. In this study, we used T1w scans from elderly participants within ageing and clinical populations to test the accuracy of existing QC tools with respect to visual QC and to establish a new quality prediction framework for clinical research use.MethodsFour datasets acquired from multiple scanners and sites were used (N= 2438, 11 sites, 39 scanner manufacturer models, 3 field strengths – 1.5T, 3T, 2.9T, patients and controls, average age 71 ± 8 years). All structural T1w scans were processed with two standard automated QC pipelines (MRIQC and CAT12). The agreement of the accept-reject ratings was compared between the automated pipelines and with visual QC. We then designed a quality prediction framework that combines the QC measures from the existing automated tools and is trained on clinical datasets. We tested the classifier performance using cross-validation on data from all sites together, also examining the performance across diagnostic groups. We then tested the generalisability of our approach when leaving one site out and explored how well our approach generalises to data from a different scanner manufacturer and/or field strength from those used for training.ResultsOur results show significant agreement between automated QC tools and visual QC (Kappa=0.30 with MRIQC predictions; Kappa=0.28 with CAT12’s rating) when considering the entire dataset, but the agreement was highly variable across datasets. Our proposed robust undersampling boost (RUS) classifier achieved 87.7% balanced accuracy on the test data combined from different sites (with 86.6% and 88.3% balanced accuracy on scans from patients and controls respectively). This classifier was also found to be generalisable on different combinations of training and test datasets (leave-one-site-out = 78.2% average balanced accuracy; exploratory models = 77.7% average balanced accuracy).ConclusionWhile existing QC tools may not be robustly applicable to datasets comprised of older adults who have a higher rate of atrophy, they produce quality metrics that can be leveraged to train a more robust quality control classifiers for ageing and clinical cohorts.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3