Safety of Non-invasive Brain Stimulation in Patients with Implants: A Computational Study

Author:

Karimi FaribaORCID,Cassarà Antonino M.ORCID,Capstick MylesORCID,Kuster NielsORCID,Neufeld EsraORCID

Abstract

AbstractObjectiveNon-invasive brain stimulation (NIBS) methodologies, such as transcranial electric (tES) and magnetic stimulation are increasingly employed for therapeutic, diagnostic, or research purposes. The concurrent presence of active or passive implants can pose safety risks, affect the NIBS delivery, or generate confounding signals. A systematic investigation is required to understand the interaction mechanisms, quantify exposure, assess safety, and establish guidance for NIBS applications.ApproachWe used measurements, simplified generic, and detailed anatomical modeling to: (i) systematically analyze exposure conditions with passive and active implants, considering local field enhancement, exposure dosimetry, tissue heating and neuromodulation, capacitive lead current injection, low-impedance pathways between electrode contacts, and insulation damage; (ii) identify safety metrics and efficient prediction strategies; (iii) quantify these metrics in relevant exposure cases and (iv) identify worst case conditions. Various aspects including implant design, positioning, scar tissue formation, anisotropy, and frequency were investigated.ResultsAt typical tES frequencies, local enhancement of dosimetric exposure quantities can reach up to one order of magnitude for DBS and SEEG implants (more for elongated passive implants), potentially resulting in unwanted neuromodulation that can confound results but is still 2-3 orders of magnitude lower than active DBS. Under worst-case conditions, capacitive current injection in the lead of active implants can produce local exposures of similar magnitude as the passive field enhancement, while capacitive pathways between contacts are negligible. Above 10 kHz, applied current magnitudes increase, necessitating consideration of tissue heating. Furthermore, capacitive effects become more prominent, leading to current injection that can reach DBS-like levels. Adverse effects from abandoned/damaged leads in direct electrode vicinity cannot be excluded.SignificanceSafety related concerns of tES application in the presence of implants are systematically identified and explored, resulting in specific and quantitative guidance and establishing a basis for safety standards. Furthermore, several methods for reducing risks are suggested.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3