VALIDATION OF A SALIVA-BASED TEST FOR THE MOLECULAR DIAGNOSIS OF SARS-CoV-2 INFECTION

Author:

Bulfoni Michela,Sozio Emanuela,Marcon Barbara,De Martino Maria,Cesselli Daniela,De Carlo Chiara,Martinella Romina,Migotti Angelica,Vania Eleonora,Zanus-Fortes Agnese,De Piero Jessica,Nencioni Emanuele,Tascini Carlo,Isola Miriam,Curcio Francesco

Abstract

ABSTRACTBackgroundSince the beginning of the pandemic, clinicians and researchers have been searching for alternative tests to improve screening and diagnosis of SARS-CoV-2 infection (Y. Yang et al., medRxiv 2020; W. Wang et al., 2020.3786; A Senok et al., Infect Drug Resist 2020). Currently, the gold standard for virus identification is the nasopharyngeal (NP) swab (N. Sethuraman et al., JAMA 2020; A.J. Jamal et al Clinical Infect Disease 2021). Saliva samples, however, offer clear practical and logistical advantages (K.K.W To et al, Clinical Microb and Infect; A.L. Wylle et al. N Engl J Med 2020; N. Matic et al, Eur J Clin 2021) but due to lack of collection, transport, and storage solutions, high-throughput saliva-based laboratory tests are difficult to scale up as a screening or diagnostic tool (D. Esser et al., Biomark Insights 2008; E. Kaufman et al., Crit Rev Oral Biol Med2002). With this study, we aimed to validate an intra-laboratory molecular detection method for SARS-CoV-2 on saliva samples collected in a new storage saline solution, comparing the results to NP swabs to determine the difference in sensitivity between the two tests.MethodsIn this study, 156 patients (cases) and 1005 asymptomatic subjects (controls) were enrolled and tested simultaneously for the detection of the SARS-CoV-2 viral genome by RT-PCR on both NP swab and saliva samples. Saliva samples were collected in a preservative and inhibiting saline solution (Biofarma Srl). Internal method validation was performed to standardize the entire workflow for saliva samples.ResultsThe identification of SARS-CoV-2 conducted on saliva samples showed a clinical sensitivity of 95.1% and specificity of 97.8% compared to NP swabs. The positive predictive value (PPV) was 81% while the negative predictive value (NPV) was 99.5%. Test concordance was 97.6% (Cohen’s Kappa=0.86; 95% CI 0.81-0.91). The LoD of the test was 5 viral copies for both samples.ConclusionsRT-PCR assays conducted on a stored saliva sample achieved similar performance to those on NP swabs and this may provide a very effective tool for population screening and diagnosis. Collection of saliva in a stabilizing solution makes the test more convenient and widely available; furthermore, the denaturing properties of the solution reduce the infective risks belonging to sample manipulation.

Publisher

Cold Spring Harbor Laboratory

Reference41 articles.

1. CDC. 2020. Coronavirus Disease 2019 (COVID-19). Centers for Disease Control and Prevention.

2. Coronavirus Disease-2019: An Overview and Update;Bengal Physician Journal,2020

3. SARS-CoV-2/COVID-19: Viral Genomics, Epidemiology, Vaccines, and Therapeutic Interventions;Viruses,2020

4. Commissioner O of the. 2020. Coronavirus (COVID-19) Update: FDA Issues Emergency Use Authorization to Yale School of Public Health for SalivaDirect, Which Uses a New Method of Saliva Sample Processing. FDA.

5. Wang W , Xu Y , Gao R , Lu R , Han K , Wu G , Tan W. 2020. Detection of SARS-CoV-2 in Different Types of Clinical Specimens. JAMA https://doi.org/10.1001/jama.2020.3786.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3