iEEG-recon: A Fast and Scalable Pipeline for Accurate Reconstruction of Intracranial Electrodes and Implantable Devices

Author:

Lucas AlfredoORCID,Scheid Brittany H.ORCID,Pattnaik Akash R.,Gallagher Ryan,Mojena Marissa,Tranquille Ashley,Prager Brian,Gleichgerrcht EzequielORCID,Gong Ruxue,Litt BrianORCID,Davis Kathryn A.ORCID,Das SandhitsuORCID,Stein Joel M.ORCID,Sinha Nishant

Abstract

BackgroundCollaboration between epilepsy centers is essential to integrate multimodal data for epilepsy research. Scalable tools for rapid and reproducible data analysis facilitate multicenter data integration and harmonization. Clinicians use intracranial EEG (iEEG) in conjunction with non-invasive brain imaging to identify epileptic networks and target therapy for drug-resistant epilepsy cases. Our goal was to promote ongoing and future collaboration by automating the process of “electrode reconstruction,” which involves the labeling, registration, and assignment of iEEG electrode coordinates on neuroimaging. These tasks are still performed manually in many epilepsy centers. We developed a standalone, modular pipeline that performs electrode reconstruction. We demonstrate our tool’s compatibility with clinical and research workflows and its scalability on cloud platforms.MethodsWe createdIEEG-recon, a scalable electrode reconstruction pipeline for semi-automatic iEEG annotation, rapid image registration, and electrode assignment on brain MRIs. Its modular architecture includes three modules: a clinical module for electrode labeling and localization, and a research module for automated data processing and electrode contact assignment. To ensure accessibility for users with limited programming and imaging expertise, we packaged iEEG-recon in a containerized format that allows integration into clinical workflows. We propose a cloud-based implementation of iEEG-recon, and test our pipeline on data from 132 patients at two epilepsy centers using retrospective and prospective cohorts.ResultsWe used iEEG-recon to accurately reconstruct electrodes in both electrocorticography (ECoG) and stereoelectroencephalography (SEEG) cases with a 10 minute running time per case, and ∼20 min for semi-automatic electrode labeling. iEEG-recon generates quality assurance reports and visualizations to support epilepsy surgery discussions. Reconstruction outputs from the clinical module were radiologically validated through pre- and post-implant T1-MRI visual inspections. Our use of ANTsPyNet deep learning approach for brain segmentation and electrode classification was consistent with the widely used Freesurfer segmentation.DiscussioniEEG-recon is a valuable tool for automating reconstruction of iEEG electrodes and implantable devices on brain MRI, promoting efficient data analysis, and integration into clinical workflows. The tool’s accuracy, speed, and compatibility with cloud platforms make it a useful resource for epilepsy centers worldwide. Comprehensive documentation is available athttps://ieeg-recon.readthedocs.io/en/latest/Graphical Abstract

Publisher

Cold Spring Harbor Laboratory

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3