Modified Long-Axis In-Plane Ultrasound Versus Short-Axis Out-of-Plane Ultrasound For Radial Arterial Cannulation: A Prospective Randomized Controlled Trial

Author:

Wang Jiebo,Zhang Liangcheng,Huang Qijian,Lai Zhongmeng,Wu Guohua,Lin Lei,Liu Junle,Weng Xianfeng

Abstract

BACKGROUNDGiven a low first-pass success rate of the conventional SAX (short-axis) or LAX (long-axis) approach, ultrasound-guided radial artery cannulation in adults with radial artery diameter less than 2.2 mm may be still challenging.OBJECTIVETo assess the efficacy of modified long-axis in-plane(M-LAIP) versus short-axis out-of-plane (SAOP) or conventional palpation(C-P) approaches for ultrasound-guided radial artery cannulation.DESIGNA prospective, randomized and controlled trial.SETTINGOperating room in a tertiary university hospital, from 1 July 2018 to 24 November 2018.PATIENTSA total of 201 patients (age 18 to 85 years, the diameter of the radial artery less 2.2 mm) were included. Patients with history of forearm surgery, ulnar artery occlusion, abnormal Allen test, etc, were excluded from this study.INTERVENTIONSAll patients were randomized 1:1:1 to M-LAIP, SAOP or C-P.MAIN OUTCOME MEASURESThe primary outcome was the cannulation success rate. Secondary outcomes included first location time and cannulation time, number of attempts.RESULTSThe cannulation success rate was significantly higher in the M-LAIP group than in the SAOP group or C-P group (first success rate: 80.3% vs 53.8% or 33.8%; p =0.000; total success rate: 93.9% vs 78.5% or 50.8%; p =0.000). First location time (s) was significantly longer in the M-LAIP group compared with the SAOP group (31(28-35[12-44]) vs 15(14-17[10-21]); p =0.000) and the C-P group (31(28-35[12-44]) vs 12(8-13.5 [6-37]); p =0.000). However, the time of cannulation in the M-LAIP group (29(24-45[16-313])) was significantly shorter than that in the SAOP group (45(28.5-135.5[14-346]), p =0.002) and in the C-P group(138(27-308[12-363]), p =0.000). The number of attempts decreased in the M-LAIP group compared with SAOP or C-P group (1.29±0.63 vs 1.8±0.89 or 2.22±0.93, p =0.000).CONCLUSIONThe M-LAIP procedure for ultrasound-guided radial artery cannulation can offer a higher success rate of the first-attempt and total cannulation, fewer attempts and less time of cannulation.TRIAL REGISTRATIONThe study was registered at ClinicalTrials.gov (http://www.chictr.org.cn/index.aspx, number: ChiCTR-IOR-17011474).

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ultrasound guidance for arterial (other than femoral) catheterisation in adults;Cochrane Database of Systematic Reviews;2021-10-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3