Blood Draw Site and Analytic Device Influence Hemoglobin Measurements

Author:

Killilea David W.ORCID,Kuypers Frans A.,Larkin Sandra K.,Schultz Kathleen

Abstract

ABSTRACTAnemia is a continuing global public health concern and a priority for international action. The prevalence of anemia is estimated from the hemoglobin (Hb) levels within target populations, yet the procedures for measuring Hb are not standardized and different approaches may result in discrepancies. Several analytical variables have been proposed to influence Hb measurements, but it is difficult to understand the impact on specific variables from large population or field studies. Therefore, we designed a highly controlled protocol that minimized most technical parameters to specifically investigate the impact of blood draw site and analytic device on Hb measurements. A diverse cohort of sixty healthy adults each provided a sequential capillary and venous blood sample that were measured for Hb using an automated hematology analyzer (ADVIA-2120) and two point-of-care devices (HemoCue 201+ and HemoCue 301). Comparing blood draw sites, the mean Hb content was 0.32-0.47 g/dL (2-4%) higher in capillary compared to venous blood from the same donors. Comparing different Hb measuring instruments, the mean Hb content was 0.19-0.46 g/dL (1-4%) higher measured with HemoCue devices compared to ADVIA-2120 in both capillary and venous blood from the same donors. The maximum variance in measurement was also higher with HemoCue devices using blood from venous (5-6% CV) and capillary (21-25% CV) sites compared to ADVIA-2120 (0.6-2% CV). Other variables including blood collection tube manufacturer did not affect mean Hb content. These results demonstrate that even when most technical variables are minimized, the blood draw site and the analytical device can have a small but statistically significant effect on the mean and dispersion of Hb measurements. Even in this study, the few participants identified as mildly anemic using venous blood measured by ADVIA-2120 would not have been classified as anemic using their capillary blood samples or point-of-care analyzers. Thus, caution is warranted when comparing Hb values between studies having differences in blood draw site and Hb measuring device. Future anemia testing should maintain consistency in these analytical variables.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3