Comparison of structural MRI brain measures between 1.5T and 3T: data from the Lothian Birth Cohort 1936

Author:

Buchanan Colin R.,Muñoz Maniega Susana,Valdés Hernández Maria C.,Ballerini Lucia,Barclay Gayle,Taylor Adele M.,Russ Tom C.,Tucker-Drob Elliot M.,Wardlaw Joanna M.,Deary Ian J.,Bastin Mark E.,Cox Simon R.

Abstract

AbstractMulti-scanner MRI studies are reliant on understanding the apparent differences in imaging measures between different scanners. We provide a comprehensive analysis of T1-weighted and diffusion MRI (dMRI) structural brain measures between a 1.5T GE Signa Horizon HDx and a 3T Siemens Magnetom Prisma using 91 community-dwelling older participants (aged 82 years). Although we found considerable differences in absolute measurements (global tissue volumes were measured as ∼6—11% higher and fractional anisotropy was 33% higher at 3T than at 1.5T), between-scanner consistency was good to excellent for global volumetric and dMRI measures (intraclass correlation coefficient [ICC] range: 0.612—0.993) and fair to good for 68 cortical regions (FreeSurfer) and cortical surface measures (mean ICC: 0.504—0.763). Between-scanner consistency was fair for dMRI measures of 12 major white matter tracts (mean ICC: 0.475—0.564), and the general factors of these tracts provided excellent consistency (ICC ≥ 0.769). Whole-brain structural networks provided good to excellent consistency for global metrics (ICC ≥ 0.612). Although consistency was poor for individual network connections (mean ICCs: 0.275 – 0.280), this was driven by a large difference in network sparsity (0.599 versus 0.334), and consistency was improved when comparing only the connections present in every participant (mean ICCs: 0.533—0.647). Regression-based k-fold cross-validation showed that, particularly for global volumes, between-scanner differences could be largely eliminated (R2 range 0.615—0.991). We conclude that low granularity measures of brain structure can be reliably matched between the scanners tested, but caution is warranted when combining high granularity information from different scanners.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3