Development and validation of a productive liquid chromatography-tandem mass spectrometry method for the analysis of androgens, estrogens, glucocorticoids and progestagens in human serum

Author:

Iannone Michele,Dima Anna Pia,Sciarra Francesca,Botrè Francesco,Isidori Andrea M.ORCID

Abstract

AbstractAdrenal and gonadal disorders are very often coupled, due to common etiology or pathophysiology. We present the development, validation and application of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous analysis of androgens (androstenedione (A4), testosterone (T), dihydrotestosterone (DHT), and dehydroepiandrosterone sulfate (DHEA-S)), estrogens (estrone (E1), estradiol (E2), estriol (E3)), glucocorticoids (cortisol (F), cortisone (E), corticosterone (B), 11-deoxycortisol (S), 21-deoxycortisol (21DF), 11-deoxycorticosterone (11DB)), and progestagens (progesterone (P4), 17α-hydroxyprogesterone (17OHP4) and 17α-hydroxypregnenolone (17OHP5)) in human serum for clinical use. Samples (250 &[mu]L of matrix) spiked with isotopic labelled internal standards were extracted with tert-butylmethyl ether (TBME) prior to LC-MS/MS analysis. The chromatographic separation of the underivatized endogenous steroids was achieved on a reversed-phase column (C18 Zorbax Eclipse Plus) using a methanol-water gradient. The LC column was coupled to a triple quadrupole mass spectrometer equipped with an electrospray (ESI) source operating both in positive and in negative mode, with acquisition in multiple reaction mode. The method was validated using surrogated matrices and human serum samples. The proposed method was proven to be specific for all the considered steroids; and linearity was also assessed (R2 > 0.99) in the ranges of quantification investigated. The lower limits of quantification (LLOQs) were in the range of 10 - 400 pg/mL depending on the target steroid. Accuracy was in the range 80 - 120% for all the target compounds, the extraction recovery was higher than 65% for all the steroids considered and no remarkable matrix effect, expressed in terms of ion enhancement and ion suppression, was observed. To test the reliability of the developed and validated method, the analysis of serum samples collected from ten healthy subjects (5M/5F) was performed. In the clinical settings there is a growing need to develop accessible methods for full steroid hormone profiling. The dynamic link between steroidogenic glands and liver enzymatic processing (activation and clearance) attributes to the profile a much greater clinical meaning than a set of individually measured hormones. The presented method can be used to identify trajectories of deviation from the concentration normality ranges applied to disorders of the gonadal and adrenal axes.

Publisher

Cold Spring Harbor Laboratory

Reference53 articles.

1. Steroid assays and endocrinology: best practices for basic scientists;Endocrinology,2014

2. Hormonal Supplementation and Erectile Dysfunction

3. The coming of age of liquid chromatography coupled to tandem mass spectrometry in the endocrinology laboratory;Journal of Chromatography B,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3