Clinical applicability of the WaveFront Phase Imaging Sensor in the Keratoconus Disease

Author:

Belda-Para Carolina,Velarde-Rodríguez Gonzalo,Velasco-Ocaña Miriam,Trujillo-Sevilla Juan M.,Rodríguez-Méndez Iván,Rodríguez-Martin Javier,Alejandre-Alba Nicolas,Rodríguez-García Silvia,Rodríguez-Ramos José M.

Abstract

AbstractSignificanceThe analysis of the wavefront phase of keratoconus eyes has become increasingly important due to its impact on the assessment of visual quality loss, irrecoverable with conventional optical treatments, and the understanding of morphological changes in corneal structures.AimThe aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the novel high-resolution ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor).ApproachThe measurements with this device were taken on healthy and keratoconic eyes at the Hospital Universitario Fundación Jiménez Díaz (Madrid, Spain). The wavefront phase recovered is post-processed and displayed in different phase maps, using exclusively the high-pass filter map for this study. From this map, the Root Mean Square, the Peak-to-Valley, and the amplitude value of the predominant obtained from its Fourier Transform are the parameters to distinguish between healthy and keratoconic eyes. Furthermore, the banding pattern observed in most keratoconic eyes is quantitatively analyzed by means of its period and orientation calculated from the Fourier Transform.ResultsThe Control group was composed of 43 healthy eyes, and the Pathological group presented 43 keratoconic eyes. Regarding the first three parameters used to compare both groups, there were significant statistical differences between them in all parameters, where the values obtained with the keratoconic group were higher than those of the healthy group. Although the values cannot be statistically comparable between stages, they tended to increase according to the severity of the disease. On the other hand, analyzing the banding pattern, the mean value of the period was approximately 50 µm, and most orientations were obliquus, tending to be horizontal rather than vertical.ConclusionsThe present study demonstrates that the objective analysis of the high frequencies detected by this wavefront sensor is a potential tool to reliably advise in the keratoconus diagnosis. Furthermore, combining this achievement with the quantitative assessment of the banding pattern would be used to objectively monitor the internal corneal status throughout the disease and its treatment optimization and surgery time.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3