Quantitative Impact of Coil Misalignment and Misplacement in Transcranial Magnetic Stimulation

Author:

Koehler Max,Kammer Thomas,Goetz Stefan M.

Abstract

AbstractIntroductionTargeting in transcranial magnetic stimulation (TMS) involves the accurate placement and positioning of the stimulation coil on the head of a subject or patient. In clinical and research applications, this placement is even done manually and/or with fixed coil holders that do not compensate for motion and drift of the head. The placement involves six degrees of freedom (DOF; three position DOF: 1× contact and 2× head location; three rotational DOF: 2× alignment and 1× electric field direction/orientation), which challenge operators. This procedure is—even with an experienced user—prone to positioning errors, which can result in low treatment efficacy or high stimulation strength due to overestimating the resting motor threshold (RMT). Whereas the position and field orientation are at least widely appreciated, the coil–head alignment and its impact are often not even known. Errors involve constant errors, drift (both leading to bias and inter-individual variability), and particularly fluctuations (causing intra-individual variability).ObjectiveWe demonstrate the impact of positioning error on cortical field strength to get a better understanding of the importance of accurate positioning and compare as well as quantify the impact of position vs. alignment errors.MethodsWe simulated the impact in a realistic head anatomy to quantify various levels of position errors and misalignment, rolling-off the coil from the target.ResultsPosition and alignment errors shift the focus of the electric field and reduce the electric field in the actual target. A misalignment of 10° can exceed the loss of stimulation strength in the target associated with a shift of 10 mm, corresponding to threshold stimulation leading to no detectable electromyographic response anymore. Misalignment in the direction of the handle (pitch), with which many operators appear to struggle most, reduces the field in the actual target faster than left–right roll.ConclusionThis work highlights the importance of the coil–head alignment for intra- and interindividual variability.

Publisher

Cold Spring Harbor Laboratory

Reference34 articles.

1. Non-invasive electrical and magnetic stimulation of the brain, spinal cord, roots and peripheral nerves: Basic principles and procedures for routine clinical and research application. An updated report from an I.F.C.N. Committee;Clinical neurophysiology official journal of the International Federation of Clinical Neurophysiology,2015

2. Non-invasive magnetic stimulation of human motor cortex;Lancet (London, England),1985

3. Prediction of Force Recruitment of Neuromuscular Magnetic Stimulation From 3D Field Model of the Thigh;IEEE transactions on neural systems and rehabilitation engineering a publication of the IEEE Engineering in Medicine and Biology Society,2022

4. Neuromodulation: present and emerging methods;Frontiers in neuroengineering,2014

5. Enhancement of human cognitive performance using transcranial magnetic stimulation (TMS)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3