Detection and Characterization of Thrombosis in Humans using Fibrin-Targeted Positron Emission Tomography and Magnetic Resonance

Author:

Izquierdo-Garcia DavidORCID,Désogère PaulineORCID,Philip Anne L.,Mekkaoui Choukri,Weiner Rory B.,Catalano Onofrio A.ORCID,Chen Yin-Ching Iris,DeFaria Yeh Doreen,Mansour Moussa,Catana CiprianORCID,Caravan PeterORCID,Sosnovik David E.

Abstract

AbstractThe detection of thrombus in the left atrial appendage (LAA) is vital in the prevention of stroke. We present a novel technique to detect and characterize LAA thrombus in humans using positron emission tomography (PET) of a fibrin-binding radiotracer, [64Cu]FBP8. Initial testing in healthy volunteers (n = 8) revealed that [64Cu]FBP8 was stable to metabolism and was rapidly eliminated with a blood half-life of one hour. Patients with atrial fibrillation (AF) and recent transesophageal echocardiograms (TEEs) of the LAA (positive n = 12, negative n = 12) were studied. PET, integrated with magnetic resonance (PET-MR), of the thorax was performed one hour after [64Cu]FBP8 injection. The maximum standardized uptake value (SUVMax) in the LAA was significantly higher in the TEE positive than negative subjects, median [interquartile range] of 4.0 [3.0–6.0] vs. 2.3 [2.1–2.5]; p < 0.001. A SUVMax threshold of 2.6 correctly identified 12/12 positive TEEs and 10/12 negative ones, yielding an area-under-the-receiver operating characteristic curve of 0.97. The minimum longitudinal magnetic relaxation time (T1Min) in the LAA was significantly shorter in the TEE positive than TEE negative group 970 [780–1080] vs. 1380 [1120–1620], p < 0.05, with some overlap between the groups. Logistic regression using SUVMax and T1Min allowed all TEE positive and negative subjects to be classified with 100% accuracy. A strong correlation was seen between fibrin (SUVMax) and methemoglobin (T1Min) content in the LAA. In conclusion, the detection of LAA thrombus in humans with PET-MR of [64Cu]FBP8 is highly accurate and provides useful information on the biological properties of cardiac thrombus.One Sentence SummaryFirst-in-human fibrin-targeted PET-MR of thrombus

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3