Abstract
AbstractThis study describes a time series-based method of middle ear muscle reflex (MEMR) detection using bilateral clicks. Although many methods can detect changes in the OAE evoking stimulus to monitor the MEMR, they do not discriminate between true MEMR-mediated vs. artifactual changes in the stimulus. We measured MEMR in 20 young clinically normal hearing individuals using 1-second-long click trains presented at six levels (65 to 95 dB peak-to-peak SPL in 6 dB steps). Changes in the stimulus levels over the 1 second period were well-approximated by two-term exponential functions. The magnitude of ear canal pressure changes due to MEMR increased monotonically as a function of click level but non-monotonically with frequency when separated into 1/3rd-octave wide bands between 1 and 3.2 kHz. MEMR thresholds estimated using this method were lower than that obtained from a clinical tympanometer in ∼94% of the participants. A time series-based method, along with statistical tests, may provide additional confidence in detecting the MEMR. MEMR effects were smallest at 2 kHz, between 1 and 3.2 kHz, which may provide avenues for minimizing the MEMR influence while measuring other responses (e.g., the medial olivocochlear reflex).