Utilization of Eco-friendly Imidazolium-Based Ionic Liquids for Gluten Extraction: Investigating the Influence of Side Chains and Anions

Author:

Chen Wen-Hao,Hsiao Yu-ChengORCID

Abstract

AbstractGluten is a well-known food allergen globally, capable of triggering immune responses in both celiac and non-celiac gluten-sensitive individuals. Gluten comprises two major proteins: glutenin and gliadin. Gliadin, in particular, possesses a unique hydrophobic amino acid sequence. The Food and Drug Administration asserts that the toxicity of gliadin cannot be eliminated through fermentation and hydrolysis processes. A common approach to addressing gluten allergies is to adopt a gluten-free diet. However, the hydrophobic nature of gluten makes its detection challenging. Analysts often resort to using organic solvents or employing multiple procedures to denature gluten for extraction. It’s worth noting that while organic solvents can rapidly extract gluten from a sample, they may also alter antibodies, leading to erroneous bio-test results.Ionic liquid (IL) is a highly adaptable green chemical compound consisting of organic salts. We modified imidazolium, a cationic structure, with various carbon side chain lengths (C=0, 1, 3, 5, 7, 9, and 12), and combined it with organic and inorganic anions (e.g., OMs-, Cl-, F-, NO¬3-, HSO4-, and H2PO4-). We used different IL-to-water ratios to assess gluten solubility. We measured the solubility of gliadin in various imidazolium ILs and conducted kinetic studies on the dissolution of gliadin in 1% [C5DMIM][OMs]aq. Additionally, circular dichroism (CD) spectroscopy and enzyme-linked immunosorbent assay (ELISA) were employed to evaluate the structural changes in gliadin and its interaction with antibodies after treatment with 1% [C5DMIM][OMs]aq. An XTT assay was conducted to assess the cytotoxicity of [C5DMIM][OMs]aq on N2a cells.Our research findings indicate that 1% [C5DMIM][OMs]aq demonstrated excellent gluten solubility, dissolving more than 3000 ppm of gluten within 5 minutes. Importantly, [C5DMIM][OMs]aq did not disrupt the gluten structure, did not impede antibody binding to gluten, and exhibited no cell toxicity. This report highlights [C5DMIM][OMs] as a promising extraction solution for gluten detection.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3