Abstract
AbstractThird-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plantBrachypodium distachyon. In all instances, aberration correction led to significant enhancements in image quality.
Publisher
Cold Spring Harbor Laboratory
Reference40 articles.
1. Two-Photon Laser Scanning Fluorescence Microscopy
2. Deep tissue two-photon microscopy;Nature Methods 2005 2:12,2005
3. In vivo three-photon microscopy of subcortical structures within an intact mouse brain;Nature Photonics,2013
4. T. Wang , C. Wu , D. G. Ouzounov , W. Gu , F. Xia , M. Kim , X. Yang , M. R. Warden , and C. Xu , “Quantitative analysis of 1300-nm three-photon calcium imaging in the mouse brain,” eLife 9, (2020).
5. Nonlinear scanning laser microscopy by third harmonic generation