Automated Discrimination of Dicentric and Monocentric Chromosomes by Machine Learning-based Image Processing

Author:

Li Yanxin,Knoll Joan H.,Wilkins Ruth,Flegal Farrah N.,Rogan Peter K.ORCID

Abstract

AbstractDose from radiation exposure can be estimated from dicentric chromosome (DC) frequencies in metaphase cells of peripheral blood lymphocytes. We automated DC detection by extracting features in Giemsa-stained metaphase chromosome images and classifying objects by machine learning (ML). DC detection involves i) intensity thresholded segmentation of metaphase objects, ii) chromosome separation by watershed transformation and elimination of inseparable chromosome clusters, fragments and staining debris using a morphological decision tree filter, iii) determination of chromosome width and centreline, iv) derivation of centromere candidates and v) distinction of DCs from monocentric chromosomes (MC) by ML. Centromere candidates are inferred from 14 image features input to a Support Vector Machine (SVM). 16 features derived from these candidates are then supplied to a Boosting classifier and a second SVM which determines whether a chromosome is either a DC or MC. The SVM was trained with 292 DCs and 3135 MCs, and then tested with cells exposed to either low (1 Gy) or high (2-4 Gy) radiation dose. Results were then compared with those of 3 experts. True positive rates (TPR) and positive predictive values (PPV) were determined for the tuning parameter, σ. At larger σ, PPV decreases and TPR increases. At high dose, for σ= 1.3, TPR = 0.52 and PPV = 0.83, while at σ= 1.6, the TPR = 0.65 and PPV = 0.72. At low dose and σ = 1.3, TPR = 0.67 and PPV = 0.26. The algorithm differentiates DCs from MCs, overlapped chromosomes and other objects with acceptable accuracy over a wide range of radiation exposures.

Publisher

Cold Spring Harbor Laboratory

Reference17 articles.

1. Bai, X , Latecki, L. J. , and Liu, W. Y. 2007. Skeleton pruning by contour partitioning with discrete curve evolution. IEEE Transactions on Pattern Analysis and Machine Intelligence. 29(3), 449-462.

2. Radiation dosimetry by automatic image analysis of dicentric chromosomes

3. International Atomic Energy Agency. 2001. Cytogenetic Analysis for Radiation Dose Assessment: A Manual. Vienna, Austria: IAEA..

4. Centromere and Length Detection in Artificially Straightened Highly Curved Human Chromosomes;Int. J. Biological Eng,2012

5. Kobayashi T He L , Shyu C-R , Knoll JHM , Rogan PK. Content and Classification based Ranking Algorithm for Metaphase Chromosome Images, IEEE Conference on Multimedia Imaging, 2004.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3