Fuzzy ripple artifact in high resolution fMRI: identification, cause, and mitigation

Author:

Huber RenzoORCID,Stirnberg RüdigerORCID,Morgan A TylerORCID,Feinberg David AORCID,Ehses PhilippORCID,Knudsen Lasse,Gulban Omer FarukORCID,Koiso KenshuORCID,Swegle StephanieORCID,Gephart Isabel,Wardle Susan GORCID,Persichetti AndrewORCID,Beckett Alexander JSORCID,Stöcker TonyORCID,Boulant NicolasORCID,Poser Benedikt AORCID,Bandettini PeterORCID

Abstract

AbstractPurposeHigh resolution fMRI is a rapidly growing research field focused on capturing functional signal changes across cortical layers. However, the data acquisition is limited by low spatial frequency EPI artifacts; termed here as Fuzzy Ripples. These artifacts limit the practical applicability of acquisition protocols with higher spatial resolution, faster acquisition speed, and they challenge imaging in lower brain areas.MethodsWe characterize Fuzzy Ripple artifacts across commonly used sequences and distinguish them from conventional EPI Nyquist ghosts, off-resonance effects, and GRAPPA artifacts. To investigate their origin, we employ dual polarity readouts.ResultsOur findings indicate that Fuzzy Ripples are primarily caused by readout-specific imperfections in k-space trajectories, which can be exacerbated by inductive coupling between third-order shims and readout gradients. We also find that these artifacts can be mitigated through complex-valued averaging of dual polarity EPI or by disconnecting the third-order shim coils.ConclusionThe proposed mitigation strategies allow overcoming current limitations in layer-fMRI protocols:Achieving resolutions beyond 0.8mm is feasible, and even at 3T, we achieved 0.53mm voxel functional connectivity mapping.Sub-millimeter sampling acceleration can be increased to allow sub-second TRs and laminar whole brain protocols with up to GRAPPA 8.Sub-millimeter fMRI is achievable in lower brain areas, including the cerebellum.

Publisher

Cold Spring Harbor Laboratory

Reference41 articles.

1. A New Phase Correction Method in NMR Imaging Based on Autocorrelation and Histogram Analysis

2. Heid, Oliver . Method for the phase correction of nuclear magnetic resonance signals, Patent: US006043651A 2000.

3. Feiweier T , inventor; Siemens Aktiengesellschaft, assignee. Magnetic resonance method and apparatus to determine phase correction parameters. US Patent 8,497,681. July 30, 2013.

4. Segmented K‐space blipped‐controlled aliasing in parallel imaging for high spatiotemporal resolution EPI

5. Layer-dependent functional connectivity methods