Deficient stereopsis in the normal population revisited: why current clinical stereo tests may not be adequate

Author:

Hess Robert F,Dillon Rebecca,Ding Rifeng,Zhou Jiawei

Abstract

AbstractSignificance statementApplied applications for occupational screening, clinical tests should assess sensitivity to the sign as well as the magnitude of disparity.PurposeTo determine why the high incidence of stereo anomaly found using laboratory tests with polarity-based increment judgements (i.e., depth sign) is not reflected in clinical measurements that involve single-polarity incremental judgements (i.e., depth magnitude).MethodsAn iPod-based measurement that involved the detection of an oriented shape defined by a single polarity-depth increment within a random dot display was used. A staircase procedure was used to gather sufficient trials to derive a meaningful measure of variance for the measurement of stereopsis over a large disparity range. Forty-five adults with normal binocular vision (20 - 65 years old) and normal or corrected-to-normal (0 logMAR or better) monocular vision participated in this study.ResultsObservers’ stereo acuities ranged between 10 and 100 arc seconds, and were normally distributed on a log scale (p = 0.90, 2-tailed Shapiro-Wilk test). The present results using a single polarity depth increment task (i.e., depth magnitude) show a similar distribution to those using a similar task using the Randot preschool stereo test on individuals between the ages of 19-35 using either the 4-book test (n = 33) or the 3-book test (n = 40), but very different results when the iPod test involved a polarity-based increment judgement (i.e., depth sign).ConclusionsThe present clinical stereo tests are based on magnitude judgements and are unable to detect the high percentage of stereo anomalous individuals in the normal population revealed using depth sign judgements.

Publisher

Cold Spring Harbor Laboratory

Reference14 articles.

1. A Robust and Reliable Test to Measure Stereopsis in the Clinic;Invest Ophthalmol Vis Sci,2016

2. Randot Preschool Stereoacuity Test: Normative Data and Validity;Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus / American Association for Pediatric Ophthalmology and Strabismus,2008

3. Visual Attention at the Tip of the Tongue

4. Anomalous Stereoscopic Depth Perception*

5. Stereopsis and stereoblindness

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3