Prostatic Peripheral Zone Thickness: What is Normal on Magnetic Resonance Imaging?

Author:

Wasserman Neil F.,Spilseth BenjaminORCID,Sanghvi TinaORCID

Abstract

AbstractPurposeTo report the precision of a technique of measuring the PZ thickness on T2-weighted MRI and report normal parameters in patients with normal-sized prostates. We also wanted to establish the mean and second standard deviations (2SD) above and below the mean as criteria for abnormally narrow or expanded PZ thickness.MethodsOf the initial 1566 consecutive cohort referred for evaluation for carcinoma based on elevated PSA (prostate specific antibody) or DRE (digital rectal examination), 132 separate subjects with normal-sized prostates were selected for this study. Mean age was 58.2 years (15-82). Median serum PSA was 6.2ng/ML (range, 0.3-145). Most were asymptomatic for lower urinary tract symptoms (LUTS). Inclusion criteria in this study required technically adequate T2-weighted MRI and total prostatic volume (TPV) ≤ 25 cc. Exclusion criteria included post prostatic surgical and radiation patients, patients having had medical management or minimally invasive therapy for BPH, those being treated for prostatitis. Patients with suspected tumor expanding or obscuring measurement boundaries were also not considered. Transition zone (TZ) and peripheral zone (PZ) volumes were determined using the prolate ellipsoid model. Postero-lateral measurement of the PZ was obtained at the axial level of maximal transverse diameter of the prostate on a line drawn from the outer boundary of the TZ to the inner boundary of the external prostatic capsule. The data was normally distributed. Therefore, it was analyzed using the 2-sided student t-test and Pearson produce correlation statistic.ResultsMean pooled (composite) measurement for the postero-lateral PZ (PLPZ) was 10 mm (CI= 9.5-10.5 mm) with SD of 2.87 mm. Means were statistically the same for the 2 observers (p=0.75). Pearson correlation between the two observers was 0.63.ConclusionsIn a prostate ≤ 25 cc volume the postero-lateral PZ should be no thicker than 15.8 mm and averages 10.0 mm. when measured in the maximal axial plane on MRI. These norms were independent of age or use of endorectal coil. The technique measurement demonstrated clinically useful precision.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3