A novel use of diffusion-weighted whole-body magnetic resonance imaging with background body signal suppression to diagnose infectious aortitis

Author:

Saito JienORCID,Muto Masahiro,Tada MasafumiORCID,Yokota Isao,Kamiya Shinji,Numata Yukihide,Sasaki Hideki,Hashizume Takuya,Asano Miki,Wakasa Satoru

Abstract

AbstractBackgroundDiffusion-weighted whole-body imaging with background body signal suppression is one of the whole-body magnetic resonance imaging techniques and is effective in diagnosing inflammatory and infectious diseases. We aimed to evaluate the diagnostic performance of this modality in infectious aortitis, which remains unclear.MethodsThe study participants were 32 patients with suspected infectious aortitis who underwent computed tomography and magnetic resonance imaging between September 2020 and November 2022. Sensitivity, specificity, and areas under the curve of each imaging modality were studied using a diagnosis based on a combination of imaging results, clinical symptoms, and laboratory tests. Decision curve analysis was performed to determine the benefit of adding magnetic resonance imaging to computed tomography.ResultsThe median age was 74 years, and 23 participants were men. Fifteen patients (47%) were diagnosed with infectious aortitis. Positive findings for infectious aortitis were identified in 19, 18, and 14 patients by computed tomography, diffusion-weighted whole-body imaging, and the combination of both modalities, respectively. Sensitivity, specificity, and area under the curve for correct diagnosis were 93.3%, 70.6%, and 0.82 (95% confidence interval 0.69–0.95), respectively for computed tomography, 93.3%, 76.5%, and 0.85% (95% confidence interval 0.73%–0.97), respectively for diffusion-weighted imaging, and 86.7%, 94.1%, and 0.90 (95% confidence interval 0.80–0.10), respectively for the combination of both modalities. Decision curve analysis reinforced the clinical benefit of combining the two imaging modalities across all ranges of the probability thresholds.ConclusionsDiffusion-weighted whole-body imaging with background body signal suppression is an effective diagnostic tool for infectious aortitis, especially when combined with computed tomography.Clinical PerspectiveInfectious aortitis is a serious disease that is difficult to accurately diagnose. Although PET-CT is associated with high diagnostic performance, limited access to this modality has encouraged the development of an alternative modality. The whole-body MRI with DWIBS is a more available modality, which is commonly used for cancer diagnosis but is also considered effective in diagnosing infectious diseases. The combination of DWIBS and non-contrast CT yielded a sensitivity of 86.7% (95% CI: 59.5–98.3%), a specificity of 94.1% (95% CI: 71.3–99.9%), and an AUC of 0.90 (95% CI: 0.80–0.10) for the diagnosis of infectious aortitis. DWIBS can be a useful modality as an alternative to PET-CT.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3