Performance of Immunological Assays for Universal and Differential Diagnosis of HTLV-1/2 Infection in Candidates for Blood Donations from the Brazilian Amazon

Author:

Santos Felipe Araujo,Catão Cláudio Lucas Santos,Martins Júlia Pereira,Pessoa Uzamôr Henrique Soares,Sousa Isabelle Vasconcelos,Melo Jean Silva,Souza Gláucia Lima,Araújo Nilberto Dias,Magalhães-Gama Fábio,Abrahim Cláudia Maria de Moura,Mourão Emmily Myrella Vasconcelos,Peruhype-Magalhães Vanessa,Coelho-dos-Reis Jordana Grazziela Alves,Teixeira-Carvalho Andréa,Vallinoto Antonio Carlos RosárioORCID,Pontes Gemilson Soares,Araújo Márcio Sobreira Silva,Martins-Filho Olindo Assis,da Costa Allyson GuimarãesORCID

Abstract

ABSTRACTThe present study compares the ability of distinct immunological assays (chemiluminescence immunoassay-CLIA, western blot-WB and flow cytometry-FC-Simplex and Duplex) to detect anti-HTLV antibodies in candidates for blood donations at the Amazonas State Blood Center (Brazil) between January 2018 and December 2022. Overall, 257,942 samples from candidates for blood donations were screened using CLIA, which led to 0.15% seropositivity for HTLV (409 samples). A total of 151 candidates for blood donations were enrolled for retesting with CLIA followed by additional testing using WB and FC-Simplex and Duplex analysis. Our results demonstrated that 62% (93/151), 20% (30/151) and 17% (26/151) of the samples presented positive results with retesting using CLIA, WB and FC-Simplex analysis, respectively. Additional analysis of the CLIA, WB and FC-Simplex results revealed an overall agreement of 56% for CLIA and WB (22 co-negative; 30 co-positive samples), 48% for CLIA and FC-Simplex (21 co-negative; 24 co-positive samples) and 80% for WB and FC-Simplex (51 co-negative; 23 co-positive samples). Considering the WB as the reference standard for the diagnosis of infection with HTLV-1/2, we observed that the CLIA results of ≤3.0 RLU and >10.0 RLU in the retest can be used define a negative or positive result, respectively, and could be used as new specific cut-off values. The overall agreement between WB and FC-Duplex for accomplishing the differential diagnosis was evaluated and demonstrated 100% correspondence for the diagnosis of HTLV-1 (15/15) and HTLV-2 (7/7). Our findings demonstrate that gaps in the diagnosis of infection with HTLV-1/2 could be overcome by the simultaneous use of distinct immunological assays during retesting of candidates for blood donations.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3