Aortic Strain in Patients with Marfan Syndrome Long-Term After Proximal Graft Replacement Surgery – Novel Insights Enabled by Cine-CMR Biomechanical Characterization

Author:

Park Robert Y.,Latvis Cole,Roman Mary J.,Kim Jiwon,Agoglia Hannah K.,Liberman Nicole,Villar-Calle Pablo,Jain Raina,Liu Sheldon,Rong Lisa,Palumbo Maria Chiara,Redaelli Alberto,Wang Yadong,Humphrey Jay D.,Devereux Richard B.,Soletti Giovanni,Gaudino Mario F.L.,Girardi Leonard N.,Weinsaft Jonathan W.

Abstract

AbstractBackgroundProsthetic graft replacement of thoracic aortic aneurysms (TAA) yields benefits but risks persist in the native aorta, especially in Marfan syndrome (MFS). Differential biomechanics between chronically grafted and native aortic regions are unknown.MethodsFunctional cardiac magnetic resonance (cine-CMR) imaging was performed in non-surgical MFS patients (root or ascending diameter≤4.5cm) and patients after (>1 year) proximal grafting. Analyses included mid-ascending and -descending aortic size (diameter, area) and compliance indices, including global circumferential strain (GCS), fractional area change (FAC), stiffness index, and distensibility.Results46 MFS patients underwent cine-CMR, including 21 with chronic proximal grafts (10.5±7.3 years post-operatively). Patients with and without grafts had similar clinical and hemodynamic characteristics. Grafted and non-grafted ascending aortic size was similar between groups (p=NS), but functional parameters differed as evidenced by decrements in GCS, FAC, stiffness index, and distensibility (all p<0.001), consistent with prosthesis-associated reductions in compliance: Proximal grafts associated with decreased ascending aortic strain (B= −7.09, p<0.001) independent of age and aortic root size. Notably, native descending aortic size was larger in post-operative patients (p<0.01), paralleled by increased GCS (p<0.001) and decreased stiffness (p=0.04). In multivariate analysis, proximal grafts associated with increased descending aortic strain when controlling for ascending aortic area (B=4.19, p<0.001) or root size (B=3.14, p=0.045).ConclusionsMarfan syndrome patients with chronic proximal aortic grafts manifest distinct vessel wall biomechanics in grafted and native regions that differ from non-surgical comparators, including decreased strain (a marker of reduced compliance) within grafted territories and increased strain in native aortic regions distal to grafts.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3