Use of the EsoGuard®Molecular Biomarker Test in Non-Endoscopic Detection of Barrett’s Esophagus among High-Risk Individuals in a Screening Population

Author:

Shaheen Nicholas J.,Othman Mohamed O.,Taunk Jawar,Chang Kenneth J.,Jaganmohan Sathya,Yachimski Patrick S.,Fang John C.,Spataro Joseph S.,Verma Suman,Lee Victoria T.,deGuzman Brian J.,Aklog Lishan

Abstract

AbstractBackground and AimsBarrett’s Esophagus (BE) is the precursor to esophageal adenocarcinoma (EAC). We aimed to assess performance, safety, and tolerability of the EsoGuard (EG) assay on samples collected non-endoscopically with the EsoCheck (EC) device (EG/EC) for BE detection in the intended-use population, meeting American College of Gastroenterology (ACG) guideline criteria (chronic gastroesophageal reflux disease (GERD) and 3+ additional risk factors).MethodsWe performed a prospective, multicenter study (NCT04293458) to assess EG performance (primary endpoint) on cells collected with EC, for detection of BE and EAC using esophagogastroduodenoscopy (EGD) and biopsies as the comparator. Twenty-four sites across the U.S. and Spain participated. EC safety and usability were assessed as secondary endpoints.Results180 male subjects aged >50 years with chronic GERD met eligibility criteria, of which 163 (90.6%) had EGD and successful EC administration. Mean age was 60.5yrs, 34.4% were obese, 56.7% had tobacco history, and 3.9% had a 1stdegree relative with BE or EAC. Of 122 samples analyzed, 93 contributed to the primary endpoint analysis. About 9% of subjects in the Primary Analysis Population had BE on EGD, none with dysplasia. Sensitivity of EG for BE was 87.5% (95% CI 47.4-99.7), specificity was 81.2% (95% CI 71.2-88.8), positive predictive value was 30.4% (95% CI 13.2-52.9), and negative predictive value was 98.6% (95% CI 92.3-99.96). Mild esophageal abrasions were observed in 1.5%; no serious adverse events were reported.ConclusionsEG/EC appears effective for BE screening. This approach provides a safe, accurate, and well-tolerated non-endoscopic alternative in high-risk patients.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3