Increased variance in second electrode accuracy during deep brain stimulation and its relationship to pneumocephalus, brain shift, and clinical outcomes: a retrospective cohort study

Author:

Hart MGORCID,Posa M,Buttery PC,Morris RC

Abstract

ABSTRACTIntroductionAccurate placement of deep brain stimulation electrodes within the intended target is believed to be a key variable related to outcomes. However, methods to verify electrode location are not universally established.Research QuestionThe aim of this study was to determine the feasibility of post-op lead localisation in clinical practice and its utility to audit our own DBS accuracy.Material and MethodsA retrospective cohort study was performed of a consecutive series of patients with Parkinson’s disease who underwent deep brain stimulation of either the globus pallidus internus (GPi) or subthalamic nucleus (STN) between 2016 and 2019. Image processing was performed using the Lead-DBS toolbox. Institutional ethical approval was granted as a review of service.ResultsIn total 38 participants met the inclusion criteria. Electrode localisation was completed in 79%. Clinical outcomes included improvement in UPDRS III of 46% and PDQ39 of 32%. Overall electrode accuracy was 0.22 +/- 0.4mm for all electrodes to the main nucleus with 9 (12%) outliers but only 3 (4%) electrodes out with 2mm from the intended target. Accuracy was worse for the second electrode implanted and in the GPi but was not affected by pneumocephalus or brain shift. Neither clinical outcomes nor the volume of activated tissue was affected by electrode accuracy.Discussion and ConclusionsA neuroimaging approach to electrode localisation allows qualitative appraisal of targeting accuracy and is feasible with routine clinical data. Such methods are complimentary to traditional co-ordinate approaches and lend themselves to developing large, collaborative, and quantitative projects.HIGHLIGHTSOverall electrode accuracy was 0.22 +/- 0.4mm with only 3 (4%) electrodes out with 2mm from the intended targetAccuracy was significantly worse in the GPi versus the STN and on the second side implantedInaccuracy occurred in the X (lateral) plane but was not related to pneumocephalus or brain shift

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3