Nasal-Swab Testing Misses Patients with Low SARS-CoV-2 Viral Loads

Author:

Callahan Cody,Lee Rose A.,Lee Ghee Rye,Zulauf Kate,Kirby James E.ORCID,Arnaout Ramy

Abstract

AbstractThe urgent need for large-scale diagnostic testing for SARS-CoV-2 has prompted pursuit of sample-collection methods of sufficient sensitivity to replace sampling of the nasopharynx (NP). Among these alternatives is collection of nasal-swab samples, which can be performed by the patient, avoiding the need for healthcare personnel and personal protective equipment.Previous studies have reached opposing conclusions regarding whether nasal sampling is concordant or discordant with NP. To resolve this disagreement, we compared nasal and NP specimens collected by healthcare workers in a cohort consisting of individuals clinically suspected of COVID-19 and outpatients known to be SARS-CoV-2 RT-PCR positive undergoing follow-up. We investigated three different transport conditions, including traditional viral transport media (VTM) and dry swabs, for each of two different nasal-swab collection protocols on a total of 308 study participants, and compared categorical results and Ct values to those from standard NP swabs collected at the same time from the same patients. All testing was performed by RT-PCR on the Abbott SARS-CoV-2 RealTime EUA (limit of detection [LoD], 100 copies viral genomic RNA/mL transport medium). We found high concordance (Cohen’s kappa >0.8) only for patients with viral loads above 1,000 copies/mL. Those with viral loads below 1,000 copies/mL, the majority in our cohort, exhibited low concordance (Cohen’s kappa = 0.49); most of these would have been missed by nasal testing alone. Previous reports of high concordance may have resulted from use of assays with higher LoD (≥1,000 copies/mL). These findings counsel caution in use of nasal testing in healthcare settings and contact-tracing efforts, as opposed to screening of asymptomatic, low-prevalence, low-risk populations. Nasal testing is an adjunct, not a replacement, for NP.

Publisher

Cold Spring Harbor Laboratory

Reference22 articles.

1. Yang Y , Yang M , Shen C , et al. Evaluating the accuracy of different respiratory specimens in the laboratory diagnosis and monitoring the viral shedding of 2019-nCoV infections. medRxiv 2020; : 2020.02.11.20021493.

2. Virological assessment of hospitalized patients with COVID-2019

3. Saliva is more sensitive for SARS-CoV-2 detection in COVID-19 patients than nasopharyngeal swabs | medRxiv. https://www.medrxiv.org/content/10.1101/2020.04.16.20067835v1 (accessed June 9, 2020).

4. CDC. Information for Laboratories about Coronavirus (COVID-19). Cent. Dis. Control Prev. 2020; published online Feb 11. https://www.cdc.gov/coronavirus/2019-ncov/lab/guidelines-clinical-specimens.html (Accessed June 10, 2020).

5. Chronological Changes of Viral Shedding in Adult Inpatients With COVID-19 in Wuhan, China

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3