Optic disc centered imaging versus quadrant imaging in retinal oximetry

Author:

Mohan AshwinORCID,Shetty Rohit,Mahendradas Padmamalini,Webers Carroll AB,Berendschot Tos TJM

Abstract

AbstractWe aimed to compare intra eye quadrant variation in retinal vessel oxygen saturation in optic disc centered versus quadrant imaging. Forty two consecutive healthy subjects were included in the study. Fifty degree optic disc centered images and images of 4 quadrants (supero-temporal - ST, supero-nasal - SN, infero-nasal - IN and infero-temporal - IT) were taken. The thickest arteriole and venule were chosen in each quadrant in the optic disc centered images. For quadrant images averaged values of 3 segments of thickest arterioles and venules, each above 100µm were chosen. The intra-eye variation between quadrants for arteriolar and venous saturation (%) was compared between optic disc centered and quadrant images. Smaller vessels (70 – 100 µm) in the quadrant images were selected to study the effect of vessel calibre on oxygen saturation. Optic disc centered images gave average arteriolar saturation (%) of 90, 94, 93 and 89 and venous saturation of 58, 60, 60 and 52 in the ST, SN, IN and IT respectively. For quadrant images the average arteriolar saturation was 94, 95, 94 and 91 and the venous saturation was 62, 60, 61 and 60 in the ST, SN, IN and IT respectively. Temporally, the saturation values were significantly different (p<0.001) between optic disc centered and quadrant images. We found no differences nasally. The average intra eye range for arterioles was 11.9 in optic disc centered versus 7.1 in quadrant images (p<0.001) and for venules was 11.6 in optic disc centered versus 7.5 in quadrant images (p<0.001). We found a positive correlation of r=0.18 between saturation and vessel calibre for arteries (p=0.001) and a negative correlation of r=-0.52 for venes (p<0.001). Quadrant imaging significantly reduced intra eye variation between quadrant measurements indicating that maybe the larger variation observed in optic disc centered images are artefactual. Differences in saturation between optic disc centered and quadrant imaging were only seen temporally. We also see physiologically reducing saturation from large arterioles to small arterioles to small venules to large venules.

Publisher

Cold Spring Harbor Laboratory

Reference12 articles.

1. Studies of retinal circulation and AV oxygen difference in man;American Clinical and Climatological Association;Transactions of the American Clinical and Climatological Association,1960

2. Automatic Retinal Oximetry

3. Retinal Vessel Oxygen Saturation in Healthy Individuals

4. NORMATIVE VALUES AND PREDICTORS OF RETINAL OXYGEN SATURATION

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3