Feasibility Study of Ferumoxtyol for Contrast-enhanced MRI of Retroplacental Clear Space Disruption in Placenta Accreta Spectrum (PAS)

Author:

Badachhape Andrew A.ORCID,Burnett Brian,Bhandari Prajwal,Devkota Laxman,Bhavane Rohan,Ghaghada Ketan B.,Yallampalli Chandrasekhar,Fox Karin A.,Annapragada Ananth V.

Abstract

AbstractIntroductionPlacenta accreta spectrum (PAS) occurs when the placenta is pathologically adherent to the myometrium. An intact retroplacental clear space (RPCS) is a marker of normal placentation, but visualization with conventional imaging techniques is a challenge. In this study, we investigate use of an FDA-approved iron oxide nanoparticle, ferumoxytol, for contrast-enhanced magnetic resonance imaging of the RPCS in mouse models of normal pregnancy and PAS. We then demonstrate the translational potential of this technique in human patients presenting with severe PAS (FIGO Grade 3C), moderate PAS (FIGO Grade 1), and no PAS.MethodsA T1-weighted gradient recalled echo (GRE) sequence was used to determine the optimal dose of ferumoxytol in pregnant mice. Pregnant Gab3-/-mice, which demonstrate placental invasion, were then imaged at day 16 of gestation alongside wild-type (WT) pregnant mice which do not demonstrate invasion. Signal-to-noise ratio (SNR) was computed for placenta and RPCS for all fetoplacental units (FPUs) with ferumoxytol-enhanced magnetic resonance imaging (Fe-MRI) and used for the determination of contrast-to-noise ratio (CNR). Fe-MRI was also performed in 3 pregnant subjects using standard T1 and T2 weighted sequences and a 3D magnetic resonance angiography (MRA) sequence. RPCS volume and relative signal were calculated in all three subjects.ResultsFerumoxytol administered at 5 mg/kg produced strong T1 shortening in blood and led to strong placental enhancement in Fe-MRI images. Gab3-/-mice demonstrated loss of hypointense region characteristic of the RPCS relative to WT mice in T1w Fe-MRI. CNR between RPCS and placenta was lower in FPUs of Gab3-/-mice compared to WT mice, indicating higher degrees of vascularization and interruptions throughout the space. In human patients, Fe-MRI at a dose of 5 mg/kg enabled high uteroplacental vasculature signal and quantification of the volume and signal profile in severe and moderate invasion of the placenta relative to a non-PAS case.DiscussionFerumoxytol, an FDA-approved iron oxide nanoparticle formulation, enabled visualization of abnormal vascularization and loss of uteroplacental interface in a murine model of PAS. The potential of this non-invasive visualization technique was then further demonstrated in human subjects. Diagnosis of placental invasion using Fe-MRI may provide a sensitive method for clinical detection of PAS.

Publisher

Cold Spring Harbor Laboratory

Reference35 articles.

1. Morbidly adherent placenta treatments and outcomes, Obstet;Gynecol,2015

2. Abnormally invasive placenta—prevalence, risk factors and antenatal suspicion: results from a large population-based pregnancy cohort study in the Nordic countries, BJOG An Int;J. Obstet. Gynaecol,2016

3. S.M.M. Baird , N.H. Troiano , B. Kennedy , Morbidly adherent placenta, J. Perinat. Neonatal Nurs. (2016). https://doi.org/10.1097/JPN.0000000000000209.

4. Placenta accreta spectrum disorders: Challenges, risks, and management strategies, Int;J. Womens. Health,2020

5. The gravid uterus: MR imaging and reporting of abnormal placentation, Abdom;Radiol,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3