Validation of a Commercial Radioimmunoassay for Measurement of Human Peripheral Oxytocin

Author:

Gerred KeenanORCID,Kapoor Amita

Abstract

ABSTRACTOxytocin (OT) is a peptide hormone synthesized in the hypothalamus and released into systemic circulation or other areas of the brain. It has a variety of physiological roles such as stimulation of uterine contractions, involvement in social behaviors, and regulation of mood. Its small size and low levels within biological matrices make it challenging to accurately measure. The goal of this study was to demonstrate the specificity of the antibody, sensitivity, and reproducibility of the Phoenix Pharmaceuticals (PP) OT radioimmunoassay (RIA) for use in human urine, serum, and saliva. Specificity of the antibody was assessed by high pressure liquid chromatography with ultraviolet (HPLC-UV) separation and assay of the fractions. Immunoreactivity was evaluated using the percent OT bound, and the fraction retention times were compared to the retention time of an intact OT standard to determine which fractions contained OT in the extracted samples. Reproducibility was assessed by running replicates of pools of each biomatrix over several assays. Sensitivity was assessed by repeated measurement of physiologically relevant low-concentration specimens. In all tested specimens the greatest reactivity in assay corresponded to the same fraction(s) as the OT standard. Only minimal reactivity was found in the other fractions, suggesting that in an unfractionated sample the antibody reacts mostly with intact OT. Reproducibility was acceptable for all specimens and the coefficient of variation (CV) ranged from 3.72-8.04% and 5.89-12.8%, for intra and inter-assay, respectively. The limits of quantitation (LOQ) were sufficient for measurement of normal values in urine (0.643 & 1.43 pg/mL), serum (1.90 pg/mL), and saliva pools (0.485 & 4.42 pg/mL). In conclusion, the PP OT RIA is specific and sensitive enough for reproducible measurement of intact OT in human peripheral biological matrices.HIGHLIGHTSThe oxytocin radioimmunoassay kit from Phoenix Pharmaceuticals is specific for intact oxytocin measured in human urine, serum, and saliva.Basal levels of oxytocin are low in peripheral biomatrices, and the sensitivity of the assay is sufficient for reproducible measurement.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3