An assessment of the fixin tplo jig to generate effective compression using a transverse fracture model

Author:

Ferringo Cassio Ricardo AuadaORCID,Diggs George,Lewis Daniel D,Banks Scott A

Abstract

AbstractThe objective of this study was to determine compressive loads that could be generated using a tibial plateau leveling osteotomy (TPLO) jig with a tensioned strand of 18-gauge stainless steel orthopedic wire in a simulated transverse fracture model. The wire was sequentially tensioned using heavy needle holders or an AO wire tightener. Recorded loads were subsequently compared to loads generated by applying a 3.5 mm limited contact-dynamic compression plate (LC-DCP) as a compression plate.Two segments of 2 cm diameter Delrin rod were placed in a testing apparatus and used to simulate a transverse fracture. A load cell was interposed between the two segments to measure the compressive loads generated during the application of the TPLO jig or the LC-DCP. Compression was generated by sequential tensioning a strand of 18-gauge wire secured through the base of the arms of the TPLO jig or by placing one or two load screws in the LC-DCP. Wires were tensioned using heavy needle holders or an AO wire tightener. Eight replicates of each construct were tested. Recorded loads were compared using a one-way repeated measures ANOVA and Tukey Honestly Significant Difference test.The wire being tensioned broke while attempting a second quarter rotation of the needle holders and when the crank handle of the AO wire tightener was advanced beyond two rotations. The mean + SD peak compressive loads recorded when tensioning the wire using the heavy needle holders and AO wire tightener was 148 ± 7 N and 217 ± 16 N, respectfully. The mean ± SD load recorded after placement of the first and second load screw in the LC-DCP was 131 ± 39 N and 296 ± 49 N, respectively. The compression generated by placing two load screws in the LC-DCP was superior to the compression generated using the jig. The maximum load recorded by tensioning the wire secured through the TPLO jig using the AO wire tightener was superior to the compression generated by placing a single load screw and tensioning the wire using needle holders.Our results demonstrate that the TPLO jig allows surgeons to compress transverse fractures or osteotomies effectively. Tensioning the AO wire tightener allows for sequential tensioning and generates superior compressive loads than tensioning wires with heavy needle holders.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3