Value CMR: Towards a Comprehensive, Rapid, Cost-Effective Cardiovascular Magnetic Resonance Imaging

Author:

Ibrahim El-Sayed H.,Frank Luba,Baruah Dhiraj,Rubenstein Jason C.,Arpinar V. Emre,Nencka Andrew S.,Koch Kevin M.,Muftuler L Tugan,Unal Orhan,Stojanovska Jadranka,Charlson John,Gore Elizabeth M.,Bergom Carmen

Abstract

AbstractCMR is considered the gold standard for measuring heart function, including cardiac volumes and mass. Further, in a single CMR exam, information about cardiac function, structure, tissue composition, and blood flow could be obtained. Nevertheless, CMR is underutilized due to long scanning times, the need for multiple breath-holds, use of a contrast agent, and relatively higher cost compared to echocardiography.In this study, we propose a rapid CMR exam based on recent developments in imaging sequences. The proposed exam is both rapid and provides comprehensive cardiovascular information without the need for a contrast agent or multiple breath-holds. The developed exam includes advanced sequences for evaluating global and regional cardiac functions, myocardial tissue characterization, and flow hemodynamics in the heart, valves, and large vessels. Time-consuming conventional sequences have been replaced by advanced sequences, which resulted in reducing scan time from > 1 hour with conventional CMR exam to <20 minutes with the proposed rapid CMR exam. Specifically, conventional two-dimensional (2D) cine and phase-contrast (PC) sequences have been replaced by optimized three-dimensional (3D)-cine and four-dimensional (4D)-flow sequences, respectively. Compared to 2D cine imaging that requires 12-16 separate breath-holds, the implemented 3D-cine sequence allows for whole heart coverage in 1-2 breath-holds; thus, reducing scan time by 80-90%. Similarly, compared to 2D PC flow imaging that requires multiple breath-holds and the presence of an experienced cardiac operator for precise prescription of the imaging planes, the implemented 4D-flow sequence allows for whole-chest coverage in ∼10-minute, free-breathing acquisition without the need for a navigator echo, which makes scan time independent of the patient’s breathing pattern. Furthermore, conventional myocardial tagging has been replaced by the fast strain-encoding (SENC) sequence, which reduces scan time from one slice per breath-hold to only one slice per heartbeat (∼1 second). Finally, T1 and T2 mapping sequences are included in this proposed exam, which allow for myocardial tissue characterization without the need for contrast. The proposed rapid exam has been tested on volunteers and measurements showed good agreement with those from conventional sequences despite the significant reduction in scan time.In conclusion, we propose a rapid, contrast-free, and comprehensive cardiovascular exam that does not require repeated breath-holds or a cardiac experienced operator to run the exam, which would result in improving cost effectiveness of CMR and increasing its adoption in clinical practice.

Publisher

Cold Spring Harbor Laboratory

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3