Comparison of a custom Photogrammetry for Anatomical CarE (PHACE) system with other Low- Cost Facial Scanning Devices

Author:

To Josiah K.ORCID,Vu Anderson N.ORCID,Ediriwickrema Lilangi S.ORCID,Browne Andrew W.ORCID

Abstract

AbstractPurposeTo compare a custom Photogrammetry for Anatomical CarE (PHACE) system with other cost-effective 3-dimensional (3D) facial scanning systems to objectively characterize morphology and volume of periorbital and adnexal anatomy.MethodsThe imaging systems evaluated include the low-cost custom PHACE system and commercial software product for the iPhone called Scandy Pro (iScandy) application (Scandy, USA), and the mid-priced Einscan Pro 2X (Shining3D Technologies, China) device and Array of Reconstructed Cameras 7 (ARC7) facial scanner (Bellus3D, USA). Imaging was performed on a manikin facemask and humans with various Fitzpatrick scores. Scanner attributes were assessed using mesh density, reproducibility, surface deviation, and emulation of 3D printed phantom lesions affixed above the superciliary arch (brow line).ResultsThe Einscan served as a reference for lower cost imaging systems because it qualitatively and quantitatively renders facial morphology with the highest mesh density, reproducibility (0.13 ± 0.10 mm), and volume recapitulation (approximately 2% of 33.5 μL). Compared to the Einscan, the PHACE system (0.35 ± 0.03 mm, 0.33 ± 0.16 mm) demonstrated non-inferior mean accuracy and reproducibility root mean square (RMS) compared to the iScandy (0.42 ± 0.13 mm, 0.58 ± 0.09 mm), and significantly more expensive ARC7 (0.42 ± 0.03 mm, 0.26 ± 0.09 mm). Similarly, the PHACE system showed non-inferior volumetric modeling when rendering a 124 μL phantom lesion compared to the iScandy and more costly ARC7 (mean percent difference from the Einscan: 4.68 ± 3.73%, 9.09 ± 0.94%, and 21.99 ± 17.91% respectively).ConclusionsThe affordable PHACE system accurately measures periorbital soft tissue as well as other established mid-cost facial scanning systems. Additionally, the portability, affordability, and adaptability of PHACE can facilitate widespread adoption of 3D facial anthropometric technology as an objective measurement tool in ophthalmology.PrecisWe demonstrate a custom system for facial photogrammetry (Photogrammetry for Anatomical CarE -PHACE) to produce 3D renderings of facial volume and morphology which compares with more expensive alternative 3D scanning technologies.

Publisher

Cold Spring Harbor Laboratory

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3