Accuracy and Reliability of a Suite of Digital Measures of Walking Generated Using a Wrist-worn Sensor: Performance Characterization Study

Author:

Kowahl Nathan,Shin Sooyoon,Barman Poulami,Rainaldi Erin,Popham Sara,Kapur Ritu

Abstract

AbstractBackground/ObjectivesMobility is a meaningful aspect of an individual’s health whose quantification can provide clinical insights. Wearable sensor technology can quantify walking behaviors (a key aspect of mobility) through continuous passive monitoring. Our objective was to characterize the accuracy and reliability performance of a suite of digital measures of walking behaviors, as critical aspects in the practical implementation of digital measures into clinical studies.MethodsWe collected data from a wrist-worn device (the Verily Study Watch) worn for multiple days by a cohort of volunteer participants without history of gait/walking impairment in a real world setting. Based on step measurements computed in 10-second epochs from sensor data, we generated individual daily aggregates (participant-days) to derive a suite of measures of walking: step count, walking bout duration, number of total walking bouts, number of long walking bouts, number of short walking bouts, peak 30-minute walking cadence, peak 30-minute walking pace. To characterize accuracy of the measures, we examined agreement with truth labels generated by a concurrent, ankle-worn, reference device (Modus StepWatch 4™) with known low error, calculating the following metrics: Intraclass Correlation Coefficient (ICC), Pearson R, Mean Error (ME), Mean Absolute Error (MAE). To characterize the reliability, we developed a novel approach to identify the time to reach a reliable readout (time-to-reliability) for each measure. This was accomplished by computing mean values over aggregation scopes ranging from 1-30 days, and analyzing test-retest reliability based on ICCs between adjacent (non-overlapping) time windows for each measure.ResultsIn the accuracy characterization, we collected data for a total of 162 participant-days from a testing cohort (N=35 participants; median observation time, 5 days). Agreement with the reference device-based readouts in the testing subcohort (n=35) for the eight measurements under evaluation, as reflected by ICCs, ranged between 0.7-0.9; Pearson R values were all greater than 0.75. For the time-to-reliability characterization, we collected data for a total of 15,120 participant days (overall cohort N=234; median observation time, 119 days). Here, all digital measures achieved an ICC between adjacent readouts > 0.75 by 16 days of wear time.ConclusionsWe characterized accuracy and reliability of a suite of digital measures that provides comprehensive information about walking behaviors in real-world settings. These results, which report the level of agreement with high-accuracy reference labels and the time duration required to establish reliable measure readouts, can guide practical implementation of these measures into clinical studies. Well-characterized tools to quantify walking behaviors in research contexts can provide valuable clinical information about general population cohorts and patients with specific conditions.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3