AbstractDuring the Covid-19 pandemic, healthcare workers were extremely vulnerable to infection with the virus and needed continuous protection. One of the most effective and widely used means of protection was the FFP2 respirator. Unfortunately, this crisis created a shortage of these masks, prompting hospitals to explore opportunities to reuse them after decontamination.An approach for assessing the filtration efficiency of decontaminated FFP2 masks has been proposed and applied to evaluate the possibilities of their safe reuse. The decontamination processes adopted are those based on moist heat or hydrogen peroxide. The approach introduces efficiency measures that define the filtration and protection capacity of the masks, which characterize both chemical and structural changes, and encompasses many techniques including scanning electron microscopy (SEM), Fourier transforms infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The test protocol was applied to mask samples that had endured different decontamination cycles and the results of their efficiency measures were compared to brand-new masks’ performances.The main result was that chemical and structural characterization of the decontaminated masks have shown no substantial change or deformation of their filter media structures. Indeed, the respiratory resistance test has shown that the results of both the FFP2 masks that have undergone a hydrogen peroxide disinfection cycle or a steam autoclave cycle remained constant with a small variation of 10 Pa from the EN149 standard. The chemical characterization, on the other hand, has shown that the filter media of the decontaminated masks remains unchanged, with no detectable chemical derivatives in its constituents.

Publisher

Cold Spring Harbor Laboratory

Reference35 articles.

1. FFP3, FFP2, N95, Surgical Masks and Respirators: What Should We Be Wearing for Ophthalmic Surgery in the COVID-19 Pandemic?;Graefes Arch. Clin. Exp. Ophthalmol,2020

2. N95 Respirators and Surgical Masks | | Blogs | CDC https://blogs.cdc.gov/niosh-science-blog/2009/10/14/n95/ (accessed Sep 30, 2020).

3. COVID-19 Decontamination and Reuse of Filtering Facepiece Respirators | CDC https://www.cdc.gov/coronavirus/2019-ncov/hcp/ppe-strategy/decontamination-reuse-respirators.html (accessed Jul 10, 2020).

4. Critical Supply Shortages — The Need for Ventilators and Personal Protective Equipment during the Covid-19 Pandemic | NEJM https://www.nejm.org/doi/full/10.1056/NEJMp2006141 (accessed Jul 10, 2020).

5. Final Report for the Bioquell Hydrogen Peroxide Vapor (HPV) Decontamination for Reuse of N95 Respirators. Final Report 2016, 46.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3