Surgical modification of deep brain stimulation lead trajectories substantially reduces RF heating during MRI at 3 T: From phantom experiments to clinical applications

Author:

Vu Jasmine,Bhusal Bhumi,Rosenow Joshua,Pilitsis Julie,Golestanirad Laleh

Abstract

AbstractIntroductionRadiofrequency (RF) induced tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during magnetic resonance imaging (MRI), resulting in strict imaging guidelines and limited allowable protocols. The implanted lead’s trajectory and its orientation with respect to the MRI electric fields contribute to variations in the magnitude of RF heating across patients. Currently, there are no consistent requirements for surgically implanting the extracranial portion of the DBS lead. This produces substantial variations in clinical DBS lead trajectories and hinders RF heating predictions. Recent studies showed that incorporating concentric loops in the extracranial trajectory of the lead can reduce RF heating, but the optimal positioning of the loop remains unknown. In this study, we systematically evaluated the RF heating of 244 unique lead trajectories to elucidate the characteristics of the trajectory that minimize RF heating during MRI at 3 T. We also presented the first surgical implementation of these modified trajectories and compared their RF heating to the RF heating of unmodified trajectories.MethodsWe performed phantom experiments to assess the maximum temperature increase, ΔTmax, of 244 unique lead trajectories. We systematically interrogated the effect of three characteristics related to the extracranial portion of the lead trajectory, namely, the number of concentric loops, the size of the loops, and the position of the loops on the skull. Experiments were performed in an anthropomorphic phantom implanted with a commercial DBS system, and RF exposure was generated by applying a high-SAR sequence (T1-weighted turbo spin echo dark fluid pulse sequence, B1+rms= 2.7 μT). Test-retest experiments were conducted to assess the reliability of measurements. Additionally, we determined the effect of imaging landmark and perturbations to the DBS device configuration on the efficacy of low-heating lead trajectories. Finally, recommended modified trajectories were implanted in patients by two neurosurgeons and their RF heating was characterized in comparison with non-modified trajectories.ResultsOur search protocol elicited lead trajectories with ΔTmaxfrom 0.09 – 7.34 °C. Interestingly, increasing the number of loops and positioning them near the surgical burr hole—especially for the contralateral lead—substantially reduced RF heating. Trajectory specifications based on the results from the phantom experiments were easily adopted during the surgical procedure and generated nearly a 4-fold reduction in RF heating.Discussion/ConclusionSurgically modifying the extracranial portion of the DBS lead trajectory can substantially mitigate RF heating during MRI at 3 T. Simple adjustments to the lead’s configuration can be readily adopted during DBS lead implantation by implementing small concentric loops near the surgical burr hole.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3