An assessment of Nano-RECall: Interpretation of Oxford Nanopore sequence data for HIV-1 drug resistance testing

Author:

Delaney Kayla Eileen,Ngobeni Trevor,Woods Conan K.,Gordijn Carli,Claassen Mathilda,Parikh Urvi,Harrigan P. Richard,van Zyl Gert UvesORCID

Abstract

AbstractIntroductionOxford Nanopore Technologies (ONT) offer sequencing with low-capital-layout sequencing options, which could assist in expanding HIV drug resistance testing to resource limited settings. However, sequence analysis remains time time-consuming and reliant on skilled personnel. Moreover, current ONT bioinformatic pipelines provide a single consensus sequence that is not equivalent to Sanger sequencing, as drug resistance is often detected in mixed populations. We have therefore investigated an integrated bioinformatic pipeline, Nano-RECall, for seamless drug resistance of low read coverage ONT sequence data from affordable Flongle or MinION flow cells.MethodsWe compared Sanger sequencing to ONT sequencing of the same HIV-1 subtype C polymerase chain reaction (PCR) amplicons, respectively using RECall and the novel Nano-RECall bioinformatics pipelines. Amplicons were from separate assays a) Applied Biosystems HIV-1 Genotyping Kit (ThermoFisher) spanning protease (PR) to reverse transcriptase (RT) (PR-RT) (n=46) and b) homebrew integrase (IN) (n=21). We investigated optimal read-depth by assessing the coefficient of variation (CV) of nucleotide proportions for various read-depths; and between replicates of 400 reads. The agreement between Sanger sequences and ONT sequences were assessed at nucleotide level, and at codon level for Stanford HIV drug resistance database mutations.ResultsThe coefficient of variation of ONT minority variants plateaued after a read depth of 400-fold implying limited benefit of additional depth and replicates of 400 reads showed a CV of ∼6 % for a representative position. The average sequence similarity between ONT and Sanger sequences was 99.3% (95% CI: 99.1-99.4%) for PR-RT and 99.6% (95% CI: 99.4-99.7%) for INT. Drug resistance mutations did not differ for 21 IN sequences; 16 mutations were detected by both ONT- and Sanger sequencing. For the 46 PR and RT sequences, 245 mutations were detected by either ONT or Sanger, of these 238 (97.1%) were detected by both.ConclusionsThe Nano-RECall pipeline, freely available as a downloadable application on a Windows computer, provides Sanger-equivalent HIV drug resistance interpretation. This novel pipeline combined with a simple workflow and multiplexing samples on ONT flow-cells would contribute to making HIV drug resistance sequencing feasible for resource limited settings.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3