Impact of AI-based Real Time Image Quality Feedback for Chest Radiographs in the Clinical Routine

Author:

Poggenborg Joerg,Yaroshenko Andre,Wieberneit Nataly,Harder Tim,Gossmann Axel

Abstract

AbstractPurposeTo implement a tool for real time image quality feedback for chest radiographs into the clinical routine and to evaluate the effect of the system on the image quality of the acquired radiographs.Materials and MethodsA real time Artificial Intelligence (AI) image quality feedback tool is developed that analyzes chest PA x-rays right after the completion of the examination at the x-ray system and provides visual feedback to the system operator with respect to adherence to desired standards of collimation, patient rotation and inspiration. In order to track image quality changes over time, results were compared to image quality assessment for images, acquired prior to system implementation.ResultsCompared to the image quality prior to the installation of the real time image quality feedback solution, it is shown that a relative increase of images with optimal image quality with respect to collimation, patient rotation and inspiration is achieved by 30% (p<0.01). A relative improvement of 28% (p<0.01) is observed for the increase of images with optimal collimation, followed by a relative increase of 4% (p<0.01) of images with optimal inspiration. Finally, a detailed analysis is presented that shows that the average unnecessarily exposed area is reduced by 34% (p<0.01).DiscussionThis study shows that it is possible to significantly improve image quality using a real time AI-based image quality feedback tool. The developed tool not only provides objective and impartial criticism and helps x-ray operators identify areas for improvement, but also gives positive feedback.Key FindingsA substantial amount of images acquired in the clinical routine does not suffice the international guidelinesContinuous AI-based image quality feedback to the x-ray system operator in the clinical routine leads to a significant image quality improvement over timeUsing the developed tool, the overall fraction of images with optimal patient positioning could be improved by 30%, followed by a 34% decrease of unnecessarily exposed area.

Publisher

Cold Spring Harbor Laboratory

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3