Design and validation of an automated radiation therapy treatment planning approach for locally advanced lung cancer

Author:

Pogue Joel A.,Cardenas Carlos E.,Harms Joseph,Soike Michael H.,Kole Adam J.,Schneider Craig S.,Veale Christopher,Popple Richard,Belliveau Jean-Guy,McDonald Andrew M.,Stanley Dennis N.

Abstract

AbstractPurposeRadiation therapy planning for locally-advanced non-small cell lung cancer (NSCLC) is challenging due to the balancing of target coverage and organs-at-risk (OAR) sparing. Using the Varian Ethos Treatment Planning System (TPS), we developed a methodology to automatically generate efficient, high-quality treatment plans for locally-advanced lung cancer patients.Methods and MaterialsFifty patients previously treated with Eclipse-generated plans for inoperable Stage IIIA-IIIC NSCLC were included in this Institutional Review Board (IRB)-approved retrospective study. Fifteen patients were used to iteratively optimize an Ethos TPS planning template, and the remaining thirty-five patients had plans automatically generated without manual intervention using the created template. Ethos and Eclipse plan quality was then assessed using 1) standard dose volume histogram (DVH) metrics, 2) adherence to clinical trial objectives, and 3) radiation oncologist qualitative review.ResultsEthos-generated plans showed improved primary and nodal planning target volume (PTVp and PTVn, respectively) V100% and V95% coverage (p<0.001) and reduced PTVp Dmax values (p=0.023). Furthermore, the Ethos template-generated plans had lower spinal cord Dmax, lungs V5Gy, and heart V25Gy, V30Gy, and V45Gy values (p≤0.021). However, Ethos esophagus metrics (mean, V35Gy, V50Gy, Dmax) and brachial plexus metrics (Dmax) were greater than Eclipse (p≤0.008), but were still clinically acceptable. A large majority (80%) of automatically generated plans had entirely “per protocol” or “variation acceptable” metrics. Three radiation oncologists qualitatively scored the Ethos plans; 78% of plans were scored as clinically acceptable during physician evaluation, with zero plans receiving scores requiring major changes.ConclusionsA standard Ethos template generated lung cancer radiotherapy plans with greater target coverage, increased spinal cord, heart, and lung V5Gy sparing, but increased esophagus and brachial plexus dose, compared to manually generated Eclipse plans. This template elucidates an efficient approach for generating automated, high quality lung radiation therapy treatment plans.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3