In Vivo and Phantom Repeatability of Diffusion-Weighted MRI Sequences on 1.5T MRI-Linear Accelerator (MR-Linac) and MR Simulator Devices for Head and Neck Cancers: Results from a Prospective R-IDEAL Stage 2a Evaluation of Tumor and Normal Tissue Apparent Diffusion Coefficients as Quantitative Imaging Biomarkers

Author:

McDonald Brigid A.ORCID,Salzillo TravisORCID,Mulder SamuelORCID,Ahmed SaraORCID,Dresner Alex,Preston KathrynORCID,He Renjie,Christodouleas John,Mohamed Abdallah S. R.ORCID,Philippens Marielle,van Houdt Petra,Thorwarth Daniela,Wang Jihong,Dave Amita Shukla,Boss Michael,Fuller Clifton D.ORCID

Abstract

AbstractIntroductionDiffusion-weighted imaging (DWI) on MRI-linear accelerator (MR-linac) systems can potentially be used for monitoring treatment response and adaptive radiotherapy in head and neck cancers (HNC) but requires extensive validation. We perform technical validation to compare six total DWI sequences on an MR-linac and MR simulator (MR sim) in patients, volunteers, and phantoms.MethodsTen human papillomavirus-positive oropharyngeal cancer patients and ten volunteers underwent DWI on a 1.5T MR-linac with three DWI sequences: echo planar imaging (EPI), split acquisition of fast spin echo signals (SPLICE), and turbo spin echo (TSE). Volunteers were also imaged on a 1.5T MR sim with three sequences: EPI, BLADE, and RESOLVE. Participants underwent two scan sessions per device and two repeats of each sequence per session. Repeatability and reproducibility within-subject coefficient of variation (wCV) of mean ADC were calculated for tumors and lymph nodes (patients) and parotid glands (volunteers). Differences in measured ADC values between sequences were quantified using Bland-Altman analysis. ADC bias, repeatability/reproducibility metrics, and SNR were quantified using a phantom.ResultsIn vivo repeatability/reproducibility wCV of mean ADC for parotids were 5.41%/6.72%, 3.83%/8.80%, 5.66%/10.03%, 3.44%/5.70%, 5.04%/5.66%, 4.23%/7.36% for EPIMR-linac, SPLICE, TSE, EPIMR sim, BLADE, RESOLVE. Repeatability/reproducibility wCV for EPIMR-linac, SPLICE, TSE were 9.64%/10.28%, 7.84%/8.96%, 7.60%/11.68% for tumors and 7.80%/9.95%, 7.23%/8.48%, 10.82%/10.44% for nodes. Bland-Altman analysis revealed significant differences between all sequence pairs except BLADE-EPIMR-linac and RESOLVE-SPLICE. All sequences except TSE had phantom ADC biases within ±0.1×10−3 mm2/s for most vials. MR-linac sequences had inconsistent ADC values between different vials with the same known ADC value, indicating spatial inhomogeneities. SNR of b=0 images was 87.3, 180.5, 161.3, 171.0, 171.9, 130.2 for EPIMR-linac, SPLICE, TSE, EPIMR sim, BLADE, RESOLVE.ConclusionMR-linac DWI sequences demonstrate near-comparable performance to MR sim sequences and warrant further clinical validation for treatment response assessment in HNC.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3