Contrast-Enhanced, Molecular Imaging of Vascular Inflammation in the Mouse Model by Simultaneous PET/MRI

Author:

Du Siyi,Ng Thomas S.C.,House Adrian,Tang Tang,Zheng Lin,Tu Chuqiao,Peake Janice,Espiritu Imelda E.,Ma Kwan-Liu,Pinkerton Kent,Jacobs Russell E.,Louie Angelique Y.ORCID

Abstract

AbstractDespite advances in diagnosis and management, cardiovascular diseases (CVDs) remain the leading cause of death in the US. Atherosclerosis is the most common form of CVD and the vulnerability of atherosclerotic plaques to rupture is a primary determinant for risk of catastrophic ischemic events. Current imaging of atherosclerotic disease focuses on assessing plaque size and the degree of luminal stenosis, which are not good predictors of plaque stability. Functional methods to identify biomarkers of inflammation in plaques could facilitate assessment of plaque instability to allow early intervention. In this study, we validate the use of a purpose-built, magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) insert for multimodal, molecular imaging of vulnerable plaques in mice. We illustrate the application of PET to screen for inflamed regions to guide the application of MRI. Molecular MRI visualizes regions of vascular inflammation and is coupled with anatomical MRI to generate detailed maps of the inflammatory marker within the context of an individual vessel. As a testbed for this imaging methodology, we developed a multimodal, iron oxide nanoparticle (NP) targeting vascular cell adhesion molecule-1 (VCAM-1) for simultaneous PET/MRI of vascular inflammation performed on a mouse carotid ligation model. In vitro cell studies confirmed that the NPs are not cytotoxic to liver cells. In vivo simultaneous PET/MRI imaging identified regions of inflammation. Three-dimensional rendering of the MRI data facilitated high-resolution visualization of patterns of inflammation along the injured vessel. Histology validated the co-localization of the NPs with VCAM-1 expression at sites of induced inflammation. The results of this work validate the utility of the simultaneous PET/MR insert as a research tool for small animals and lays groundwork to further advance the potential clinical utility of integrated imaging systems.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3