A Nomogram to Predict Pneumothorax Requiring Chest Tube Placement following Percutaneous CT-guided Lung Biopsy

Author:

Bondarenko MashaORCID,Zhang Jianxiang,Baal Ulysis Hugo,Lam Brian,Chaudhari GunvantORCID,Lee Yoo Jin,Schroeder Jamie,Vella MayaORCID,Haas BrianORCID,Vu Thienkhai,Kallianos KimberlyORCID,Liu Jonathan,Sridhar Shravan,Elicker BrettORCID,Sohn Jae HoORCID

Abstract

ABSTRACTBackgroundPneumothorax requiring chest tube after CT-guided transthoracic lung biopsy is one of the common complications, and the required hospital stay after chest tube placement represents an added clinical risk to patients and cost to the healthcare system. Identifying high-risk patients can prompt alternative biopsy modes and/or better preparation for more focused post-procedural care.PurposeTo develop and externally validate a risk nomogram for pneumothorax requiring chest tube placement following CT-guided lung biopsy, leveraging quantitative emphysema algorithm.Materials & MethodsThis two-center retrospective study included patients who underwent CT-guided lung biopsy from between 1994 and 2023. Data from one hospital was set aside for validation (n=613). Emphysema severity was quantified and categorized to 3-point scale using a previously published algorithm based on 3×3×3 kernels and Hounsfield thresholding, and a risk calculator was developed using forward variable selection and logistic regression. The model was validated using bootstrapping and Harrell’s C-index.Results2,512 patients (mean age, 64.47 years +/-13.38 [standard deviation]; 1250 men) were evaluated, of whom 157 (6.7%) experienced pneumothorax complications requiring chest tube placement. After forward variable selection to reduce the covariates to maximize clinical usability, the risk score was developed using age over 60 (OR 1.80 [1.15-2.93]), non-prone patient position (OR 2.48 [1.63-3.75]), and severe emphysema (OR 1.99 [1.35-2.94]). The nomogram showed mean absolute error of 0.5% in calibration and Harrell’s C-index of 0.664 in discrimination in the internal cohort.ConclusionThe developed nomogram predicts age over 60, non-prone position during biopsy, and severe emphysema to be most predictive of pneumothorax requiring chest tube placement following CT-guided lung biopsy.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3