Initial Experience with Intercostal Insertion of an Extravascular ICD Lead Compatible with Existing Pulse Generators

Author:

Burke Martin C.,Knops Reinoud E.ORCID,Reddy VivekORCID,Aasbo Johan,Husby MichaelORCID,Marcovecchio AlanORCID,O’Connor Mark,Sanghera RickORCID,Scheck Don,Pepplinkhuizen Shari,Ebner Adrian

Abstract

Structured AbstractObjectivesThis study assessed safety and feasibility of a novel extravascular (EV) implantable cardioverter-defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket.BackgroundCurrently available or investigational, EV-ICDs include a subcutaneous or subxiphoid lead connected to customized EV-ICD PGs. This novel EV-ICD (AtaCor Medical, Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs.MethodsIn this non-randomized, single-center, acute study, 36 de novo or replacement transvenous (TV) ICD patients enrolled to receive a concomitant EV-ICD lead inserted through an intercostal space along the left parasternal margin. EV-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped down in 10 J increments following conversion success and stepped up in 5 J increments following conversion failure.ResultsSuccessful acute defibrillation using ≤ 35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3 ± 8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0 ± 8.4 J). All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed.ConclusionsThis first-in-human study documented safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD pulse generators.Condensed AbstractThis study assessed feasibility of intercostal implantation of a novel extravascular implantable cardioverter-defibrillator (ICD) lead designed to function with commercial DF-4 pulse generators (PGs). Lead placement was successful in 33 of 36 attempts (94%). Acute defibrillation with ≤35 J was successful in 27 of 27 left mid-axillary PG subjects (100%) and 5 of 6 left pectoral PG subjects (83%). All evaluable episodes (n=93) were automatically detected. No serious device-related intraoperative adverse events were observed. This study demonstrates feasibility of a novel extravascular ICD lead with effective sensing and defibrillating of induced ventricular fibrillation using commercial DF-4 PGs.

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3