Measurement of Water Depth in a Class A Pan Using Ultrasonic Transducer and Programmable Logic Control (PLC)

Author:

GENÇOĞLAN Cafer1ORCID,GENÇOĞLAN Serpil2ORCID,USTA Selçuk3ORCID

Affiliation:

1. KAHRAMANMARAŞ SÜTÇÜ İMAM ÜNİVERSİTESİ

2. KAHRAMANMARAŞ SÜTÇÜ İMAM ÜNİVERSİTESİ, ZİRAAT FAKÜLTESİ, BİYOSİSTEM MÜHENDİSLİĞİ BÖLÜMÜ

3. VAN YÜZÜNCÜ YIL ÜNİVERSİTESİ, VAN MESLEK YÜKSEKOKULU

Abstract

The aim of this study is to compare water depths measured by manually and PLC from a Class A Pan in field conditions using ultrasonic transducer. The study was conducted in garden of Faculty of Agriculture, University of Kahramanmaras Sutcu Imam in the summer season of 2019. A steel meter was used to measure water depth manually in the evaporation pan. Using the ultrasonic transducer, PLC measured water depth from the evaporation pan between 140 and 223 mm water depth at 8:00 am. An ultrasonic transducer is attached one end of sliding buttress, at which was 50 cm above from its inner-bottom at the center of the evaporation pan. The ultrasonic transducer was set to be able to read water depth and calibrated using sliding buttress. A program was written in CODESYS-ST language to measure the water depth from a Class A Pan using PLC, which was connected the ultrasonic transducer and uploaded to PLC. With the program, digital water depths were converted to millimeter water depths. To be able to read the water depth more accurately, each depth value read by the PLC was determined by averaging 30 measurements made successively at 300 millisecond intervals. In this processes, moving average method was used. Water depth measured by PLC was saved on the SD (secure digital memory) card. In the manual water depth measurements, there were 26 observations. The water depths on the manual measurement dates were matched with the water depths measured by PLC. A regression analysis was performed between the water depths measured by the steel meter and PLC in the pan, and determination coefficient (R2) was result as 0.96. The Mean Absolute Percent Error (MAPE) of these two data sets was calculated as 2.3%. The level of agreement between the two data sets; if the MAPE is below 10%, it is considered “very good”. The results of this study revealed that the PLC could measure the water depth close to the measured manually water depth in the evaporation pan with an ultrasonic transducer.

Publisher

Tekirdag Ziraat Fakultesi Dergisi

Subject

Pollution,General Agricultural and Biological Sciences

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3