STUDI KARAKTERISTIK BATA MERAH LOKAL BALI SEBAGAI DINDING

Author:

Rita Rahayu Ni Nyoman,Budiwati I. A. M,Sukrawa M.

Abstract

Abstract : This study was conducted to determine the characteristics of brick red walls. Red brick taken from a local brick manufacturer Gianyar, Tabanan and  Negara refer to SNI 15-0686-1989. By using mortar 1: 4, 1: 5, 1: 6, 1: 7 and 1: 8, according to the rules SK SNI M-111-1990-03. Testing red brick wall refers to the standards set in SNI 03-4164-1996. The data measured in this study is the compressive strength, modulus of elasticity and flexural strength. Modulus of elasticity of the wall pair by way of experiment calculated using the equation defined BSEN 1052-1-1999 Brick walls Gianyar, Tabanan of mortar 1: 4 consecutive compressive strength characteristics are 1.22, 1.32 and 1.42 N / mm ². Based on the results obtained in the testing of masonry walls with mortar 1: 4 with the value of the average compressive strength of 11.13 N / mm ² are classified as class mortar (i) according to standard BS 5628-1-1992 characteristic compressive strength for all wall below the chart value pairs are characteristic compressive strength of masonry that is equal to 2.5 N / mm ². Average modulus of elasticity of masonry walls Gianyar of mortar 1: 4, 1: 5, 1: 6, 1: 7 and 1: 8, according to the equation obtained 1052-1-1999 BSEN 240, 191, 171, 156 and 154 N / mm ², masonry walls Tabanan of mortar 1: 7 and 1: 8 obtained elastic modulus of 356 and 344 N / mm ², masonry walls Negara of mortar 1: 7 and 1: 8 obtained elastic modulus of 363 and 348 N / mm ².  When compared three types of masonry is based on the elastic modulus and compressive strength, then the resulting brick wall of Negara has the greatest value for the various types of mortar, followed by a later brick wall brick wall Tabanan, Gianyar. Flexural strength values ??by using the equations listed in SNI 03-4165-1996,  for gianyar masonry walls with mortar 1: 4, 1: 5, 1: 6, respectively are 0.005, 0.004 , 0.004 N/mm2, brick Tabanan 0.009, 0.007, 0.005 0.009 N/mm2 and brick Negara, 0.008, 0.006 N/mm2. Testing by means of BS EN 1052-2-1999 be reviewed only for 1:4 mortar masonry walls flexural strength values ??produced an average of 0.0045 MPa, this value is very close to the value obtained from way SNI 03-4165-1996 is equal to 0.005 MPa.

Publisher

Universitas Udayana

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3