Analysis: Intravascular Devices with a Higher Risk of Polymer Emboli: The Need for Particulate Generation Testing

Author:

Chopra Amitabh Madhukumar,Rapkiewicz Amy,Daggubati Ramesh,Sequeira Adrian,Hu Yin C.,Bhatt Deepak L.,Sharma Samin K.,Cruz Juan Pablo,Tzafriri Abraham R.,Edelman Elazer R.

Abstract

Abstract Hydrophilic polymer coatings on intravascular devices lower friction between the device and vasculature, thereby reducing trauma during interventional procedures. Polymer coating embolism—the detachment and downstream embolism of polymer particles—has been reported as an iatrogenic complication of coated interventional devices affecting the vasculature and various organs. The Food and Drug Administration (FDA) acknowledges this complication and continues to work with stakeholders to close gaps in performance testing and standards related to polymer coating integrity. Recent innovations within interventional technologies have led to development of new hydrophilic-coated devices with expanded indications for use. The 2018 FDA draft guidance for intravascular guidewires expands the application of particulate generation testing to most devices and recommends labeling changes to increase industry awareness. This article highlights current procedural trends where the phenomenon of polymer coating embolism may be more prevalent. It describes the mechanisms of polymer separation, reported clinical sequelae, and risk factors for relevant indications. These procedural trends and associated risk factors articulate the need for particulate testing and support the FDA's draft guidance recommendations for performance testing of applied coatings. If standardized, particulate assessments may allow characterization and comparisons of coating integrity among devices from various manufacturers, and are an important foundation for setting particulate limits. As hydrophilic coatings enable endovascular treatment for a range of patient populations, setting particulate limits or finding alternative solutions without compromise to device function may be essential. Particulate testing is relevant to physicians, regulators, and manufacturers for the purposes of product development and quality improvement of interventional devices.

Publisher

Association for the Advancement of Medical Instrumentation (AAMI)

Subject

Computer Networks and Communications,Biomedical Engineering

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3