Determination of Aflatoxin M1 in Liquid Milk, Cheese, and Selected Milk Proteins by Automated Online Immunoaffinity Cleanup with Liquid Chromatography‒Fluorescence Detection

Author:

Wood Jackie E1ORCID,Gill Brendon D1ORCID,Indyk Harvey E1,Rhemrev Ria2,Pazdanska Monika2,Mackay Naomi2,Marley Elaine2

Affiliation:

1. Fonterra Co-operative Group Ltd, P.O. Box 7, Waitoa 3341, New Zealand

2. R-Biopharm Rhône Ltd, Block 10 Todd Campus, West of Scotland Science Park, Acre Road, Glasgow G20 0XA, Scotland

Abstract

Abstract Background Aflatoxins are secondary metabolites produced by a number of species of Aspergillus fungi. Aflatoxin M1 (AFM1) is a hydroxylated metabolite of aflatoxin B1 and is found in the milk of cows fed with feed spoilt by Aspergillus species. AFM1 is carcinogenic, especially in the liver and kidneys, and mutagenic, and is also an immunosuppressant in humans. Objective A high-throughput method for the quantitative analysis of AFM1 that is applicable to liquid milk, cheese, milk protein concentrate (MPC), whey protein concentrate (WPC), whey protein isolate (WPI), and whey powder (WP) was developed and validated. Method AFM1 in cheese, milk, and protein products is extracted using 1% acetic acid in acetonitrile with citrate salts. The AFM1 in the resulting extract is concentrated using RIDA®CREST/IMMUNOPREP® ONLINE cartridges followed by quantification by HPLC‒fluorescence. Results The method was shown to be accurate for WP, WPC, WPI, MPC, liquid milk, and cheese, with acceptable recovery (81–112%) from spiked samples. Acceptable precision for WP, WPC, WPI, MPC, liquid milk, and cheese was confirmed, with repeatabilities of 4–12% RSD and intermediate precisions of 5–13% RSD. Method detection limit and ruggedness experiments further demonstrated the suitability of this method for routine compliance testing. An international proficiency scheme (FAPAS) cheese sample showed that this method gave results that were comparable with those from other methods. Conclusions A method for high-throughput, routine testing of AFM1 is described. The method was subjected to single-laboratory validation and was found to be accurate, precise, and fit-for-purpose. Highlights An automated online immunoaffinity cleanup HPLC‒fluorescence method for milk proteins, cheese, and milk was developed and single-laboratory validated. It allows for high-throughput analysis of AFM1 and can be used for the analysis of AFM1 in whey protein products.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3